• HVHIPOT Double Clamp Multi-function Ground Resistance Tester
  • HVHIPOT Double Clamp Multi-function Ground Resistance Tester
  • HVHIPOT Double Clamp Multi-function Ground Resistance Tester
  • HVHIPOT Double Clamp Multi-function Ground Resistance Tester

HVHIPOT Double Clamp Multi-function Ground Resistance Tester

Display Type: Analogue Only
Certification: ISO
Customized: Non-Customized
Interference voltage: <20V (should be avoided)
Interference current: <2A (should be avoided)
Power supply: DC 6V 4.5Ah lead-acid battery lasts more than 10
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GD2571C
Test voltage waveform
Sine wave
Test frequency
128Hz
Short circuit test current
AC 20mA max
Open circuit test voltage
AC 28V max
Ground resistance (Re)
0-30.00 KΩ
AC current
1000A
Transport Package
Standard Export Wooden Box
Specification
277.2mm× 227.5mm× 153mm
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9031809090
Production Capacity
5000sets/Year

Product Description

General Information

GD2571C Double Clamp Multi-function Ground Resistance Tester is the advanced grounding resistance tester integrates a variety of measurement methods. In addition to the traditional function of ground resistance measurement with auxiliary rod, the instrument also has the unique function of ground resistance measurement without auxiliary rod. Adopts large LCD gray screen backlight display and microprocessor technology, through the microprocessor-controlled 2-wire, 3-wire, 4-wire, selective method, double clamp method to test ground resistance.  Large-diameter current clamp design, double jaw measurement technology, without auxiliary rod and no need to isolate the grounding body and equipment to achieve on-line measurement. Widely used in telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding networks, lightning rods and so on. The instrument has the characteristics of precise, fast, simple, stable and reliable.
 
GD2571C Double Clamp Multi-function Ground Resistance Tester is controlled by a microprocessor and can accurately detect ground resistance, soil resistivity, ground voltage, DC resistance and AC current. It uses a fast filtering technique to minimize interference. Displaying the resistance value of the auxiliary electrode in the same screen, which is convenient for judging the measurement error caused by environmental factors, facilitating more accurate measurement of the true ground resistance value, and storing 500 sets of data at the same time. 
It can monitor data online through monitoring software, upload USB data to PC, and has unique functions such as numerical holding and intelligent alarm prompt.
 
GD2571C Double Clamp Multi-function Ground Resistance Tester consists of host, monitoring software, test lead, USB cable, and grounding rod. It has the functions of reading, checking, saving, reporting and printing of historical data. 

 

Specifications
 

Range and Accuracy

Test Function Range Accuracy Resolution
2, 3, 4 wire method for measuringground resistance (Re) 0.00Ω~29.99Ω ±2%rdg±5dgt (remark 1) 0.01Ω
30.0Ω~299.9Ω ±2%rdg±3dgt 0.1Ω
300Ω~2999Ω ±2%rdg±3dgt
3.00 kΩ~30.00 kΩ ±2%rdg±3dgt 10Ω
DC resistance(R-) 0.0Ω~299.9Ω ±2%rdg±3dgt 0.1Ω
300Ω~2999Ω ±2%rdg±3dgt
3.00kΩ~30.00kΩ ±2%rdg±3dgt 10Ω
Selective method for measuring ground resistance(Re) 0.00Ω~29.99Ω ±2%rdg±5dgt (remark 1) 0.01Ω
30.0Ω~299.9Ω ±2%rdg±3dgt 0.1Ω
300Ω~3000Ω ±2%rdg±3dgt
Double clamp method for measuring ground resistance (Re) 0.01Ω~0.99Ω ±10%rdg±10dgt 0.01Ω
  0.1Ω
 
Soil resistivity(ρ) 0.00Ωm~99.99Ωm ρ=2πaR (remark 2) 0.01Ωm
100.0Ωm~999.9Ωm  ρ=2πaR (remark 2) 0.1Ωm
1000Ωm~9999Ωm 1Ωm
10.00kΩm~99.99kΩm 10Ωm
100.0kΩm~999.9kΩm 100Ωm
1000kΩm~9999kΩm 1kΩm
Ground voltage AC 0.00~100.0V ±2%rdg±3dgt 0.01V
AC current AC 0.0mA~1000A ±2%rdg±3dgt 0.1mA

 

Remark:
1. Reference conditions: accuracy with Rh Rs < 100Ω.
Working conditions: Rh max=3kΩ+100R<50kΩ; Rs max=3kΩ+100R<50kΩ
Depends on the measurement accuracy of R, π=3.14, a:1 m~100m;



 

General specification

 
Function Ground resistanceSoil resistivityDC resistance,Ground voltageAC current
Ambient temperature and humidity 23ºC±5ºCbelow 75%rh
Interference voltage <20V (should be avoided)
Interference current <2A (should be avoided)
Electrode space whenmeasuring R a>5d
Electrode space when measuring ρ a>20h
Power supply DC 6V 4.5Ah lead-acid battery lasts more than 100 hours standby
Backlight Controllable backlight, suitable for use in dim places
measurement mode Precise four-wire, three-wire measurement, simple two-wire measurement, selective method, double clamp method for measuring grounding resistance
Measurement methods 234-wire method measurement: change-pole method, measuring current 20mA Max
Soil resistivity: four-pole method
Selective method measurement: change-pole methodmeasuring current 20mA Max
Double clamp method: non-contact mutual inductance measurement method, test current 1mA Max
DC resistance: change-pole method
AC current: average rectification (clamp)
Ground Voltage: Average Rectification(between S-ES interface)
Test voltage waveform Sine wave
Test frequency 128Hz
Short circuit test current AC 20mA max
Open circuit test voltage AC 28V max
Electrode space range 1m~100m
Display mode 4-bit large LCD display, with backlight
Measurement instructions LED flashing indicator during measurement
LCD size 111mm×68mm
LCD display field 108mm×65mm
Instrument size L*W*H277.2mm×227.5mm×153mm
Clamp size L*W*H: 101mm×27mm×214mm
Test lead stripsred 15mblack 15m, yellow 10mgreen 10m
Simple test lead 2 stripsyellow 1.5mgreen 1.5m
Auxiliary grounding rod 4PCSφ10mm×200mm
Current clamp 2PCSφ4 mm Banana plug
Current clamp diameter φ50mm
Current clamp lead Length 2m
Measure time AC currentabout 2 times/sec;
Ground voltageabout 2 times/sec;
grounding resistancesoil resistivity: about 7 seconds/time
Line voltage Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power)
USB interface With USB interface, storage data can be uploaded to the computer, save and print
Communication Line One USB communication line, 1.5m long
Data hold "HOLDSymbol indicates
Data storage 500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full
Data review Data review function: "MR" symbol display
Overflow display Over-range overflow function: "OL" symbol display
Current clamp low current indication When measuring by the selective method or the double-clamp method, when the current signal received by the current clamp A is lower than 0.5 mA, the symbol "" is displayed, and at this time, the clamping direction of the current clamp A should be checked.
Interference test Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V
Auxiliary grounding test With auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ)
Alarm function Alarm when the measured value exceeds the alarm setting value
Battery voltage Real-time display of battery power, reminding timely charging when battery voltage is low
Automatic Shutdown "APO" Indicates, automatic shutdown after 15minutes
Power consumption Standby: 40mA Max(Backlight off)
Turn on backlight: 43mA Max
Measuring120mA Max(Backlight off)
Weight Instrument2450g(including battery)
Current clamp940g(2PCS)
Test leads1300g(including simple test lead)
Auxiliary grounding rod850g(4PCS)
Working temperature and humidity -10ºC~40ºCbelow 80%rh
Storage temperature and humidity -20ºC~60ºCbelow 70%rh
Overload protection Grounding resistance measurement: AC 280V/3 seconds between H-E and S-ES ports
Insulation resistance More than 20MΩ(500V between circuit and housing)
Withstand voltage AC 3700V/rms(between circuit and housing)
Electromagnetic properties IEC61326(EMC)
Suitable for safety regulations IEC61010-1(CAT III 300VCAT IV 150Vpollution level 2);
IEC61010-031;
IEC61557-1(grounding resistance);
IEC61557-5(soil resistivity);
JJG 366-2004;
JJG 366-2004(ground resistance meter);
JJG 1054-2009(Clamp grounding resistance meter);

 

Accessories

Instrument 1PC
Instrument bag 1PC
Auxiliary grounding rod 4PCS
Current clamp 2PCS
Monitoring software CD 1PC
USB communication cable 1PC
Test lead 4PCS
Simple test lead 2PCS
6V Battery (built-in) 1PC
charger 1PC
Manual, certificate 1SET

 

HVHIPOT Double Clamp Multi-function Ground Resistance Tester
HVHIPOT Double Clamp Multi-function Ground Resistance Tester
HVHIPOT Double Clamp Multi-function Ground Resistance Tester
HVHIPOT Double Clamp Multi-function Ground Resistance Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now