HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
  • HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
  • HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
  • HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
  • HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
  • HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
Find Similar Products

Basic Info.

Model NO.
GDSL-A-1000A/6V
Type
Universal Testing Machine
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Time measurement range
0 ~ 9999ms
Secondary current range
0 ~ 5A, resolution 0.1A.
Voltage
6V
Current
1000A, other is customized
Transport Package
Standard Export Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
Production Capacity
5000set/Year

Product Description

1000A 6V Three Phase Primary Current Injection Test Set

General Information

GDSL-A-1000 intelligent primary current injection test set is a current generator designed by HV Hipot based on the country's latest power industry standards with practical experience.

It combines the advantages of similar products at home and abroad. It adopts numerical control technology and has strong anti-interference ability. It uses low-power, large-capacity self-regulating regulator and high-permeability iron core. The converter has the advantages of large output power, small size and light weight.

It is mainly used for the entire group transmission test of bus protection and various current transformers, motor protectors, air switches, switch cabinets, circuit breakers, protective screens and other verification.


Features
 
  1. 320*240 LCD screen display, high-speed thermal printer
  2. High-precision sensor and high-performance 14-bit AD acquisition chip.
  3. Optional conventional primary current test, impact quick-break test and transformer ratio change polarity test, the operation is flexible and simple.
  4. Real-time display of output current and time results, the display is intuitive and clear.
  5. Perfect over-current protection, arbitrarily set the target output current value, current upper limit and current-resistant time.
  6. With zero return detection function, the test can be performed only after the zero return is determined, which is safe and reliable.
  7. Approximation current-up algorithm, automatic current-proof timing after reaching the set target output current, and the motor will automatically return to zero after the timing is over.
  8. When the set output current upper limit is exceeded, the motor automatically returns to zero and an audible and visual alarm occurs.
  9. Sophisticated software and hardware anti-interference design, multiple anti-interference methods, adapt to harsh electromagnetic environment.
  10. Optional remote communication, door interlock warning light alarm, opening voltage verification interface, etc.


Functions
 
  1. The current can be adjusted smoothly and continuously with accuracy of 1.0 grade;
2. The output current is a standard sine wave, and the waveform distortion rate is less than 5%
3. Time measurement range: 0 ~ 9999ms, resolution 1ms, measurement error: 0.005% of range±2digs.
4. It can directly display the test value of primary current and secondary current, which is convenient for transformer ratio verification test.
5. Secondary current range 0 ~ 5A, resolution 0.1A.
6. Equipment capacity is designed for 5 minutes short-term, intermittent work.
7. If used for batch test, after 2.5 minutes of continuous work, shut down for 10 minutes.
8. It can measure the current operating time of the tested component, and can record the locking operating time simultaneously. (optional)
9. If with temperature rise function (30 minutes~24 hours), it should be customized according to long-term working temperature rise. (optional)
10. Can be customized three-phase with current regulator with balance adjustment (optional)
11. Can be customized AC and DC dual current booster (optional)


Specifications
 

Model
Output capacity
(kVA)
Output current
(A)
Power Supply
(V)
Open circuit voltage
(V)
Power phase
 
Mark
GDSL-A-500 3 500 220 6 LN Integrated
GDSL-A-1000 6 1000 220 6 LN Integrated
GDSL-A-1500 9 1500 220 6 LN Integrated
GDSL-A-2000 12 2000 220 or 380 6 LN ,AB Integrated or combination
GDSL-A-2500 15 2500 220 or 380 6 LN ,AB Integrated or combination
GDSL-D-3000 18 3000 220 or 380 6 AB Integrated or combination
GDSL-D-4000 24 4000 380 6 AB combination
GDSL-D-5000 30 5000 380 6 AB combination
GDSL-D-6000 36 6000 380 6 AB combination
GDSL-D-8000 48 8000 380 6 AB combination
GDSL-D-10000 60 10000 380 6 AB combination
GDSL-D-12000 72 12000 380 6 AB combination
GDSL-D-15000 90 15000 380 6 AB combination
Can be customized due to customer;s special requirements

HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
HVHIPOT 1000A 6V Three Phase Primary Current Injection Test Set
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier