Basic Info.

Model NO.
GDHG-206
Test Mode
Instant Test
Usage
CT/PT calibrator
Test Region
CT/PT
Power
Electricity
Certification
CE
Customized
Customized
CT Turns Ratio Range
5A/5A- 25000A/5A (5A/1A- 5000A/1A)
PT Turns Ratio Range
Full range measurement ±0.2%
Accuracy of PT/CT Error
±0.05%
CT Secondary Burden
1-25 ohm ±2%
PT Secondary Burden
1VA-500VA ±2%
Ratio Error
0.001%-3% (100V)
Angle Error
0.00′-50′ (100V)
Delivery Time
15-20 days
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9030849000
Production Capacity
5000 Sets/Year

Product Description

General introduction

GDHG-206 CT/PT On-site Calibrator is designed for analyzing current transformers and voltage transformers of ratio error, angle error, ratio error/angle error of 1%-200% current. It can directly measure turns ratio and polarity, actual secondary burden of CT/PT.
The model uses DC and AC power supply with high precision and automatic linear adjustment. High speed and reliable digital processing module is also adopted.


Different types

  • GDCT-103B CT On-site Calibrator(with white screen)
  • GDCT-103C CT On-site Calibrator (with true color big screen)
  • GDPT-103 PT On-site Calibrator
  • GDPT-103C CVT On-site Calibrator

Specifications

CT Turn Ratio Range 5A/5A- 25000A/5A (5A/1A- 5000A/1A)
Turn ratio error ±0.2%
PT Turn Ratio Range Full range measurement ±0.2%
Accuracy of PT, CT Error ±0.05%
DC Resistance 0.0-0.1ohm ±3%
0.1-50 ohm ±1%
CT Secondary Burden 1 ohm -25ohm ±2%
PT Secondary Burden 1VA-500VA ±2%
Ratio Error 0.001%-3% (100V)
Angle Error 0.00'-50' (100V)
Admittance 0.1ms-99.9ms
Error X= ±(2%×X+2%×Y±2digit), Y= ±(2%×X+2%×Y±2digit)

Different types of CT/PT calibrator are available

HVHIPOT CT PT Calibrator On-site GDHG-206 On-site multifunction calibrator