After-sales Service: yes
Warranty: 1 year
Power Supply: AC220V, 50Hz
Output: 0-150kV
Capacity: 10kVA
HV Source: Insulation Oil (Oil type testing transformer)
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDYD-1510A
Humidity
85% RH
Weight
Control Unit: about 18kg
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030332000
Production Capacity
5000 Pieces/Year

Product Description

GDYD-1510A 10kVA.150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer
HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer


GDYD-1510A Automatic AC Hipot Test Set is composed of automatic control unit and AC oil type testing transformer (HV unit) which output AC voltage smoothly. Meanwhile, it has many monitoring and protection functions.



Features

  1. 7inch color LCD screen, with PLC automation control.
  2. HV Voltage, LV voltage, LV current measured at the same time, with high precision sensor and high-performance collection chip.
  3. Automatic mode and manual mode for option.
  4. Display HV voltage, LV voltage, LV current, time, and withstanding result.
  5. Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set.
  6. Support stage voltage increasing, total 3stages, each stage voltage can be set, which is convenient to find object problem.
  7. Support automatic control of increasing speed, total 6ranges to be selected, 0.5kV/s, 1kV/s, 1.5kV/s, 2kV/s, 2.5kV/s, 3kV/s.
  8. Zero-starting function. Test can be proceeded after the voltage is back to zero.
  9. Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk.
  10. When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero.
  11. When the LV current is over setting value, the voltage will be cut off automatically and it will be back to zero. When the HV current is over setting value, the test object will be cut off and test can be proceeded continuously.
  12. With anti-interference ability, suitable for electromagnetic environment.
  13. With wheels for both control unit and HV unit, easy to move.

Specifications
 
A.Control unit specifications
  1. Power: AC220V, 50Hz
  2. Capacity: 10kVA
  3. Output voltage: AC 0-250V
  4. Rated output current: 50A
  5. Rated current rectified range: 0-50A
  6. HV voltmeter range: 0-150kV
  7. Accuracy: 2.0% of the reading±1digit (F.S)
  8. HV ammeter range: 0-67mA
  9.     Accuracy: 2.0% of the reading±1digit (F.S)
  10. LV ammeter range: 0-50A
  11.     Accuracy: 2.0% of the reading±1digit (F.S)
  12. Timing range: 1s-99h
  13. Weight: about 75kg
  14. Dimension: 570mm (L)*530mm (W)*1040mm (H)

B. Testing transformer (HV unit) specifications
  1. Input voltage: 0-200V
  2. Input current: AC 0-50A
  3. Output voltage: AC 0-150kV
  4. Output current: AC 66.6mA
  5. Capacity: 10kVA
  6. HV side/LV side turns ratio: 750:1
  7. Measuring voltage: AC 0-100V
  8.     Accuracy: 2.0% of the reading±1 digit (F.S)
  9. No-load current: <10%
  10. Impedance voltage: <10%
  11. Weight: about 180kg
  12. Dimension: 580mm(L)*440mm(W)*1280mm(H)

C. Working conditions
 
  1. Working place: No gas, steam, chemical dust, and explosive and corrosive medium which will influence insulation.
  2. Environment temperature: -20--50ºC
  3. Environment humidity: 85% RH (no condensing)
 

Accessories

Control Unit                                           1set
Oil type testing transformer (HV unit)    1set
Power cord                                                              1 piece
Metering cable                                                      1 piece
Output cable                                                          1 piece
HV cable                                                                  1 piece
Ground cable                                                        1 piece
User's guide                                                          1 piece
Factory test report                                             1 piece

HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer

HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer
HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer
HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer
HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer

HVHIPOT GDYD-1510A 10kVA 150kV Automatic AC Hipot Test Set With Oil Type Testing Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now