HVHIPOT GDAG-58A 50kV 8 Positions AC Hipot Test Set PLC Control Insulation Gloves Boots Tools Test Set for Insulated Gloves Boots
Product Description
Insulation Gloves (Boots) Test Set is special equipment for batch test of insulated gloves (boots). The test procedure is simple and personnel security is guaranteed. Parameters such as leakage current, insulation aging and frequency voltage could be obtained reliably. It can test 8pcs insulated gloves (boots) at the same time.
It is used to test insulation performance for 35kV and below insulation gloves, boots. It can test six insulation gloves/boots at one time.
Features
- The instrument can simultaneously test eight insulating boots or gloves and measure the leakage current of each specimen.
- The insulating shoe test uses a dry testing method with small steel balls inside, eliminating the traditional method of filling shoes with water for testing, which is difficult to dry afterward.
- High and low voltage are separated, and the leakage current is transmitted back to the control box using anti-interference wireless transmission technology, greatly protecting personal safety.
- Each test specimen has a disconnection mechanism. When any circuit breaks down or exceeds the set leakage current value, the test specimen on that circuit will automatically disconnect from the test, without affecting the testing of other specimens.
- 7-inch TFT touch screen LCD display with English characters, displaying a large amount of information. It simultaneously displays the test voltage, eight high-voltage leakage currents, a perpetual calendar, timing time, and other parameters, as well as Chinese prompts.
- The withstand voltage test is fully automatic, using a DC motor to control the voltage regulator's boosting process. After the test begins, the instrument automatically closes the circuit breaker and automatically increases the voltage at the rate required by national standards. Timing begins once the predetermined voltage is reached, and the test voltage is maintained. Upon timing, the voltage automatically decreases until it reaches zero, then automatically cuts off the power, indicating the end of the test. Simultaneously, the leakage current of each test sample is displayed, and the test results are automatically saved.
- The insulating boot test has a dedicated metal grounding tray, and the insulating glove test has a dedicated container for easy operation.
- Overcurrent protection function.
Operating Conditions
- Power Supply Voltage: 220V±10% 50HZ±1% Waveform Distortion Rate ≤5%
- Ambient Temperature: -5ºC to 40ºC
- Ambient Humidity: ≤80%RH, no condensation, no instrument flickering
- Altitude: ≤1000m
- The operating environment should be free from significant dust, smoke, corrosive gases, flammable gases, water vapor, and salt spray, and free from severe vibration.
Standards
DL/T474.4-2018 Guide for insulation test on site: AC Withstand Voltage Test
DL/T848.2-2018 General technical specification of high voltage test device: Power Frequency High Voltage Testing Device
GB/T16927.1-2011 High-voltage test techniques - Part 1: General Definitions and Test Requirements
DL/T 976-2017 Preventive test code of tools, devices and equipment for live working
DL/T 1476-2023 Preventive test code for electrical safety tools and device
GB21148-2020 Foot protection: Safety Footwear
GB/T 17622-2008 Live working - Gloves of insulating material
Product Parameters
Specifications
Control Unit
- Input Voltage: AC220V±10% 50Hz±1
- Output Capacity: 5kVA
- Low Voltage Output: AC 0~250V Resolution: 0.01V
- Output Current: 0-25A (Max) Resolution: 0.01A
- High Voltage: AC0~50kV Resolution: 0.01KV
- Leakage Current: AC0~30mA Resolution: 0.01mA
- Timing Range: 0~9999S
- Voltage Accuracy: ≤1% of reading ±3 digits
- Current Accuracy: ≤1% of reading ±3 digits
- Dimensions: 480*380*390 mm
- Weight: 20KG
Transformer
- Output Capacity: 5kVA
- Low Voltage (Input) Voltage: AC 0~200V
- Low Voltage (Input) Current: AC 0~25A
- High Voltage (Output) Voltage: AC 0~50kV
- High Voltage (Output) Current: 0~100mA
- Measuring Turns Ratio: 500:1; Error: ±1%
- Impedance Voltage: ≤12%
- No-Load Current: ≤10%
- Operating Time: Intermittent duty cycle with 5 minutes on and 5 minutes off at rated capacity; can operate continuously at 1/3 rated voltage and 1/3 rated current.
- Dimensions: 330*250*650 mm
- Weight: 45KG
Intelligent Testing Device for Insulating Gloves (Boots) - Leakage Current Measurement and Control Platform
- Test Stations: 8
- Leakage Current Measurement Range: AC 0~30mA Resolution: 0.01mA
- Equipment Specifications: 100*760*1150 mm
- Weight: 50KG