• Capacitance and Dissipation Factor Tester for Transformer (GD6800)
  • Capacitance and Dissipation Factor Tester for Transformer (GD6800)
  • Capacitance and Dissipation Factor Tester for Transformer (GD6800)
  • Capacitance and Dissipation Factor Tester for Transformer (GD6800)

Capacitance and Dissipation Factor Tester for Transformer (GD6800)

Anti-Interference Method: Frequency Conversion
Power Supply: AC 220V±10%
High Voltage Output: 0.5kv~10kv
Self-Excitation Power: AC 0~50V/15A
Resolution: Tgδ: 0.001%, Cx: 0.01PF
Storage Capacity: 80 Groups
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GD6800
Dimensions
430(L)*330(W)*330(H) mm
Transport Package
Wooden Case
Specification
SGS, ISO
Trademark
HV Hipot
Origin
Wuhan China
HS Code
8501109990
Production Capacity
1000PCS/Year

Product Description

Capacitance and Dissipation Factor Tester for Transformer (GD6800)


General Information  


GD6800 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipments. It can also test dielectric loss of insulating oil test grounded, which is micro controller operated, accurate, small, light weight and reliable. The device is built-in dielectric loss bridge ,variable frequency voltage regulator power ,booster and SF6 high stability standard capacitor .
 


Features

Large LCD touching screen 

Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.

With USB port.Check and manage the data and create working report in any PC by our special softwar.

Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, forward/backward connection, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.

Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVTtransformation ratio and voltage angle difference.

High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.

Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.

No need to dismantle cable to measure dielectric loss and capacitance of CVT.

High voltage boost transformer inside, with functions of over zero switch-on and lightning protection. Different level of output high voltage with 0.5kV-10kV, easy wiring.
 


Specifications
 
Working conditions -15ºC~40ºC RH < 80%
Anti-interference method Frequency conversion
Power supply AC 220V±10% Generator can be used.
High voltage output 0.5KV~10KV Every 0.1kV
Accuracy 2%
Maximum Current       200mA
Capacity 1500VA
Self-excitation power AC 0~50V/15A 45Hz/55Hz
Resolution tgδ: 0.001% Cx: 0.01pF
Accuracy tgδ: ± (Reading*1.0% + 0.040%)
Cx: ± (Reading*1.0% + 1.00pF)
Measuring range tgδ Without limit

Cx
 
15pF < Cx < 300nF
10kV Cx < 60nF
5kV Cx < 150 nF
1kV Cx < 300 nF
CVT Test  Cx < 300 nF
CVT transformation ratio Range: 10~10000
Accuracy: 0.1%
Resolution: 0.01
Dimensions 430(L)*330(W)*330(H) mm
Storage capacity 80 groups. (USB disk storage is supportable.)
Weight Control unit:27kg (carrying box included.)
Accessories:6kg (carrying box included.)


Capacitance and Dissipation Factor Tester for Transformer (GD6800)
Capacitance and Dissipation Factor Tester for Transformer (GD6800)
Capacitance and Dissipation Factor Tester for Transformer (GD6800)
Capacitance and Dissipation Factor Tester for Transformer (GD6800)
Capacitance and Dissipation Factor Tester for Transformer (GD6800)


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now