GDYD series AC hipot test set is composed of automatic control unit and AC gas testing transformer(HV unit) which output AC voltage smoothly. It is suitable for testing boom truck.
Features
7inch color LCD screen, with PLC automation control.
HV Voltage, LV voltage, LV current measured at the same time, with high precision sensor and high-performance collection chip.
Automatic mode and manual mode for option.
Display HV voltage, LV voltage, LV current, time, and withstanding result.
Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set.
Support stage voltage increasing, total 3stages, each stage voltage can be set, which is convenient to find object problem.
Support automatic control of increasing speed, total 6ranges to be selected, 0.5kV/s, 1kV/s, 1.5kV/s, 2kV/s, 2.5kV/s, 3kV/s.
Zero-starting function. Test can be proceeded after the voltage is back to zero.
Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk.
When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero.
When the LV current is over setting value, the voltage will be cut off automatically and it will be back to zero. When the HV current is over setting value, the test object will be cut off and test can be proceeded continuously.
With anti-interference ability, suitable for electromagnetic environment.
With wheels for both control unit and HV unit, easy to move.
Specifications
Control unit specifications
Power: AC240V,50Hz two phase
Capacity: 6.5kVA
Output voltage: AC 0-250V
Rated output current: 26A
HV voltmeter range: 0-130kV, tap voltage range: 0-36kV
Accuracy: 1.5% of the reading±1digit (F.S)
HV ammeter range: 0-50mA
Accuracy: 2.5% of the reading±1 digit(F.S)
Timing range:1s-99h
Weight: approx. 35kg
Dimension: approx.370mm (L)*470mm (W)*500mm (H)
B. Testing transformer (HV unit) specifications
Input voltage: 0-200V
Input current: AC 0-35A
Output voltage: AC 0-140kV, 0-36kV
Output current: AC 50mA, DC194mA
Capacity: 6.5kVA
HV side/LV side turns ratio: 700:1
Measuring voltage: AC 0-100V
Accuracy: 1.0% of the reading±1 digit(F.S)
No-load current: <10%
Impedance voltage: <10%
Weight: approx. 125kg
Dimension: 550mm(L)*630mm(W)*1350mm(H)
C. Working conditions
Working place: No gas, steam, chemical dust, and explosive and corrosive medium which will influence insulation.