AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • Compact and Lightweight Design: Smaller size and lighter weight compared to same voltage level reactors.
  • High Stability and Protection: Large capacity margin with strong protection and good stability.
  • Precise Frequency Control: 16-digit frequency resolution with fineness up to 0.1Hz.
  • Pure Sine Wave Output: THD <1.0% with orthogonal non-synchronous fix type carrier modulation.
  • Flexible Configuration: Different type reactors optional to meet various test object requirements.
  • Wide Application Scope: Ideal for substations, GIS, SF6 switches, cables, and transformers.
  • Dry Type Epoxy Cast: High mechanical strength, good insulation, and reliable performance.
  • Convenient Power Supply: Supports 220V or 380V single phase power for easy onsite sourcing.

Product Images of AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus

AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus pictures & photos
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus pictures & photos
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus pictures & photos
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus pictures & photos
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus pictures & photos
AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
  • AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
  • AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
    AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
  • AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
    AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
  • AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
    AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
  • AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
    AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
  • AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus
    AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus

Find Similar Products

Product Description

AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus

General introduction


GDTF series Substation Electrical Apparatus AC Resonance Test System, is mainly composed of frequency conversion control power, incentives transformers, reactors, capacitor divider, designed for substation electric
Equipment AC withstand voltage test of the voltage with 220KV or below. It satisfy capacitive equipment AC withstand voltage test of transformer, GIS systems, SF6 switches, cables, casing.

This Series can meet high voltage, low current device test conditions requirement, also meet low voltage, high current device test conditions requirement, with a wide scope of application, is ideal test equipment for power department, repair engineering units and high voltage testing department.


Features

1. Smaller size, lighter weight compared with same voltage level, same capacity reactor.
2. Small temperature rise at rated load. Dry type epoxy cast, high mechanical strength, good insulation, nice and reliable;
3. Large capacity margin for frequency control source. Strong protection, good stability. with multiple working mode, easy to operate;
4. with 220V or 380V single phase power, convenient for onsite power sourcing;
5. Flexible configuration. Different type reactors for optional, can meet different test object requirements. Multifunctional, cost effective;
6. Imported SPWM digital waveform generated chip. 16 digit frequency resolution. Frequency fineness up to 0.1Hz at frequency of 20-300Hz;
7. Orthogonal non-synchronous fix type carrier modulation mode, ensure good output waveform for the entire frequency range.
8. Advanced IPM module, ensure stability and security of apparatus;


Specifications
 
Rated output voltage 0 ~ 800kV (AC ) and below;
Output frequency 20 ~ 300Hz;
Waveform of Resonance voltage Pure sine wave, THD <1.0%;
Max. Test capacity 1000kVA and below;
Duty Cycle Full power output, continuous working time of 15min;
Quality factor 30 ~ 90
Frequency adjustment sensitivity 0.1Hz, instability <0.05%
Power Supply 380/220V +-15% / 50Hz +-5%

AC Resonance Test System (GDTF-HTS) for Substation Electrical Apparatus

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What equipment can this system test?
It is designed for AC withstand voltage tests of transformers, GIS systems, SF6 switches, cables, and casings.
What is the rated output voltage range?
The rated output voltage is 0 ~ 800kV (AC) and below.
What is the output frequency range?
The output frequency ranges from 20 ~ 300Hz.
What is the maximum test capacity?
The max test capacity is 1000kVA and below.
How long can the system work continuously?
It supports full power output with a continuous working time of 15 minutes.
What is the quality factor range?
The quality factor ranges from 30 ~ 90.
What is the frequency adjustment sensitivity?
The sensitivity is 0.1Hz with instability less than 0.05%.
What power supply does the system require?
It requires 380/220V +-15% / 50Hz +-5% power supply.
What is the waveform quality of the resonance voltage?
The waveform is a pure sine wave with THD <1.0%.
Is the system suitable for low voltage high current devices?
Yes, it meets the test conditions for both high voltage low current and low voltage high current devices.