Customization: | Available |
---|---|
Display Type: | Digital Only |
Certification: | ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The AC Insulation Tester is electric safety device. It is neat and compact structure with mature technology. It is widely used for household appliance, instrument and components etc.
Input | Voltage: 110V or 220VAC, ±10%, single phase Frequency: 47-63Hz Fuse: 4A/250VAC |
AC withstand test | Rated output: 5kV AC |
Output frequency | 50Hz or 60Hz, for option |
Output waveform | Sine wave, 1.3<crest factor<1.5 |
Upper limit setting of leak current | Range: 0.01-12.00mA Resolution: 0.01mA Accuracy: ±(2% of setting value+2digit) |
Lower limit setting of leak current | Range: 0.00-12.00mA Resolution: 0.01mA Accuracy: ±(2% of setting value+2digit) |
DC withstand voltage test | Rated output: 6KV DC |
Upper limit setting of leak current | Range: 0.01-6.00mA Resolution: 0.01mA Accuracy: ±(2% of setting value+2digit) |
Lower limit setting of leak current | Range: 0.00-6.00mA Resolution: 0.01mA Accuracy: ±(2% of setting value+2digit) |
Voltage setting | Range: 0-5000V AC 0-6000V DC Resolution: 1V Accuracy: ±(2% of setting value+5V) |
Voltage stability | ±(1% of setting value+5V) |
Slow rising time | Range: 0.1-999.9S |
Resolution: 0.1S | |
Accuracy: ±(0.1% of setting value+0.05S) | |
Test time | Range: 0.5-999.9S, 0 is continuous testing |
Resolution: 0.1S | |
Accuracy: ±(0.1% of setting value+0.05 S) | |
Arc detection | Range: class 1 to class 9 can be set, 0 is non-detection arc status |
Voltage display | Range: 0-5.00KV AC 0-6.00KV DC Resolution: 0.01KV Accuracy: ±(3% of display value+3digit) |
Current display | Range: 0.01-12.00mA AC 0.01-6.00mA DC Resolution: 0.01mA Accuracy: ±(2% of display value+3digit) |
Insulation resistance test | Rated output: 1000V DC |
Voltage setting | Range: 500 - 1000V DC Resolution: 100V Accuracy: ±(2% of setting value+5V) |
Voltage display | Range: 0.50KV - 1.00KV DC Resolution: 0.01KV Accuracy: ±2% of display value |
Resistance display | Range: 1.000 - 2000MΩ Accuracy: ±(5% of display value+3digit) (1-1000MΩ) ±(10% of display value+3digit)(1000-2000MΩ) |
Upper limit setting of resistance | 0-2000MΩ, 0 is non determination |
Lower limit setting of resistance | 1.0-999.9MΩ |
Delay time of determination | Range: 0.8 - 999.9 S, 0 is continuous determination Resolution: 0.1S Accuracy: ±(0.1% of display value+0.05 S) |
Dimension | 326x102x380mm |
Weight | 9kg |