HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • High Accuracy Measurement: Accuracy grade 1 with resolution up to 0.01ms for time and 0.01m/s for velocity.
  • Comprehensive Test Functions: Measures time, velocity, travel, bounce, current, and operation voltage for 12 contacts.
  • Built-in Adjustable Power Source: Integrated DC30-250V/20A source for automatic LV action tests and voltage measurement.
  • Strong Anti-Interference Capability: Reliable operation even in live 500kV substations with interbus voltage present.
  • Universal Sensor Compatibility: Supports optional universal, linear, and rotary velocity sensors for easy installation.
  • Data Storage and Printing: Built-in real-time clock, data storage, and printer for immediate waveform and data retrieval.
  • Wide Application Range: Suitable for SF6, GIS, vacuum, and oil circuit breakers across various power systems.

Product Images of HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester

HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester pictures & photos
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester pictures & photos
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester pictures & photos
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester pictures & photos
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester pictures & photos
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester pictures & photos
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
    HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
    HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
    HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
    HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
    HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
  • HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
    HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester

Find Similar Products

Product Description

GDKC-12A High Voltage Circuit Breaker Tester Transformer Test Device
 

High voltage circuit breaker is one of the most important control equipment in the power system. 

GDKC-12A is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. 




Features
  • Time: the open/close time, in phase synchronization, phase-to-phase synchronization of 12contacts.
  • Reclose: close-open, open-close, open-close-open time for each contact.
  • Bounce: Close bounce time, times, process and waveform of each contacts.
  • Velocity: Velocity at contact touch, maximum speed, time-range characteristic curve. 
  • Travel: Total travel, open travel, over travel, travel overshoot, bounce amplitude.
  • Current: open/close current, current waveform diagram of the open/close coil.
  • Operation voltage: built-in DC30~250V/20A digital, adjustable power source of breaker, automatically complete LV action test of circuit breaker and measure action voltage value of circuit breaker. 
  • It is suitable to test the mechanism parameters of all types of SF6 circuit breaker, GIS combination electric equipment, vacuum circuit breaker, oil circuit breaker.
  • Strong anti-interfere ability. It also can easily test and accurately measure even interbus is live in 500kV substation.
  • With universal velocity sensor(optional), linear velocity sensor, rotary sensor, easy to install.
  • Only one time action to obtain all data and corresponding waveform of breaker mechanism test.
  • Storage test data, built-in real-time clock, which is convenient to save test date and time.
  • LCD screen display, with contrast adjustment and power-off memory.
  • Built-in printer, to get all data and diagram at any time quickly.



Specification


1.1 Using Environments
Input Power: 220V± 10% 50Hz± 10% Air Pressure: 86~106kpa
Temperature: -10~40 degree
Humidity: 80%RH

1.2 Safety Performance
Insulation Resistance>2MΩ
Dielectric Strength: Chassis can withstand voltage 1.5kv and power frequency for 1 minute without flash-over and arcing.

1.3 The Basic Parameters

A. Time: Range 25000.0ms resolution 0.01ms
Error 250ms 0.01ms ± 1digit
         2500ms 0.1ms ± 1digit
         25000ms 1ms ± 1digit
Same period
B. Velocity: Range 20.00m / s resolution 0.01m / s
Error 0-2m / s ± 0.1m / s ± 1digit
Above 2ms ± 0.2m / s ± 1 digit

C.Range: 
  Range Resolution Error
Vacuum breaker 50.0mm 0.1mm  
0.1±1digit
SF6 circuit breaker 300.0mm 1mm
Oil circuit breaker 600.0mm

D. Current: Range 20.00A resolution 0.01A
E. Output power: DC0 ~ 300V digital adjustable / 20A (instantaneous work), resolution 1V.
F. Dimensions: 360mm (L) × 280mm (W) × 300mm (H)
G. Weight: 10kg







HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester

HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
HVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer TesterHVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer TesterHVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer TesterHVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer TesterHVHIPOT GDKC-12A High Voltage Circuit Breaker Transformer Tester
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the warranty period for this tester?
The product comes with a 1-year warranty.
Can this device test different types of circuit breakers?
Yes, it is suitable for SF6, GIS, vacuum, and oil circuit breakers.
What is the maximum speed resolution?
The velocity resolution is 0.01m/s with a maximum range of 20m/s.
Does the device have a built-in power source?
Yes, it includes a built-in DC30-250V/20A adjustable power source.
Is the device suitable for use in live substations?
Yes, it has strong anti-interference ability and can test in live 500kV substations.
What are the operating temperature and humidity limits?
It operates in temperatures from -10 to 40 degrees Celsius and up to 80% RH humidity.
Does the manufacturer offer ODM services?
Yes, ODM service is available for this product.
What is the lead time for orders?
The average lead time is one month for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now