VLF-34  AC Hipot Test Set 30kV VLF Test Set

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • IEC Recommended 0.1Hz Test: Highly recommended by IEC for testing large capacitance equipment like cables and motors.
  • Smart Quick Intelligent System: Features ARM7 microcontroller and digital frequency conversion for stable, automated operation.
  • Integrated Trolley Design: Compact, lightweight structure with trolley design for convenient indoor and outdoor transport.
  • Wide Frequency Selection: Test frequencies of 0.1Hz, 0.05Hz, and 0.02Hz are selectable to ensure a wide test range.
  • User-Friendly Interface: Equipped with capacitive touch screen, LCD display, and automatic storage and printing functions.
  • Low Insulation Damage: VLF test causes slight insulation damage compared to DC tests, ensuring equipment safety.
  • No Capacity Rising Effect: Adopts closed-loop negative feedback circuit to prevent capacity rising during outputting.

Product Images of VLF-34  AC Hipot Test Set 30kV VLF Test Set

VLF-34  AC Hipot Test Set 30kV VLF Test Set
VLF-34  AC Hipot Test Set 30kV VLF Test Set pictures & photos
VLF-34  AC Hipot Test Set 30kV VLF Test Set
VLF-34  AC Hipot Test Set 30kV VLF Test Set pictures & photos
VLF-34  AC Hipot Test Set 30kV VLF Test Set
VLF-34  AC Hipot Test Set 30kV VLF Test Set pictures & photos
VLF-34  AC Hipot Test Set 30kV VLF Test Set
VLF-34  AC Hipot Test Set 30kV VLF Test Set pictures & photos
VLF-34  AC Hipot Test Set 30kV VLF Test Set
VLF-34  AC Hipot Test Set 30kV VLF Test Set pictures & photos
VLF-34  AC Hipot Test Set 30kV VLF Test Set
  • VLF-34  AC Hipot Test Set 30kV VLF Test Set
  • VLF-34  AC Hipot Test Set 30kV VLF Test Set
    VLF-34  AC Hipot Test Set 30kV VLF Test Set
  • VLF-34  AC Hipot Test Set 30kV VLF Test Set
    VLF-34  AC Hipot Test Set 30kV VLF Test Set
  • VLF-34  AC Hipot Test Set 30kV VLF Test Set
    VLF-34  AC Hipot Test Set 30kV VLF Test Set
  • VLF-34  AC Hipot Test Set 30kV VLF Test Set
    VLF-34  AC Hipot Test Set 30kV VLF Test Set
  • VLF-34  AC Hipot Test Set 30kV VLF Test Set
    VLF-34  AC Hipot Test Set 30kV VLF Test Set

Find Similar Products

Product Description

VLF-34 VLF AC Hipot Test Set Very Low Frequency Hi-pot Test Set




General introduction

Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.

Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test.

 
Aspects DC Power Frequency Variable Frequency 0.1Hz
Equivalency poor good good good
Insulation Damage strong slight slight slight
Operation Safety relatively low relatively low relatively low high
Wiring Difficulty complicated complicated most complicated simple
Volume smallest largest large small

In fact VLF test is the substitute for power frequency test. It is suitable for testing electrical equipment with large capacitance(like power cable, power capacitor, motor and generator).


Description

The new generation of VLF series 0.1Hz VLF AC Hipot Test Set developed by HV Hipot adopts "Smart Quick" intelligent power test system (Soft No. 1010215, trademark registration number 14684781), HVHIPOT company introduced the latest international power electronic components and the latest ARM7 microcontroller technology, further reducing the size and weight of the equipment. The operation is easier and the performance is more stable.


Features
 
  1. Advanced technology adopts digital frequency conversion technology, fully automatic microcomputer control, voltage boost, step-down, measurement, protection, etc.
 
  1. Control part and High-voltage part adopt an integrated structure design, and only a high voltage wire and ground wire are needed to connect to the tested product without the intermediate connection wire.
 
  1. Trolley-style design is convenient for transportation in various working environments, and its small size and light weight are very conducive to outdoor operations(80kV).
 
  1. Over-voltage protection and over-current protection. Action time is no longer than 10ms.
 
  1. The control unit and the booster are connected at low voltage, with photoelectric isolation control, safe and reliable to use.
 
  1. Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
 
  1. Capacitive touch screen, LCD graphic display, automatic storage and printing.
 
  1. 0.1Hz, 0.05Hz and 0.02Hz can be chosen, which ensures a wide test range.






Specifications
 
  1. Peak voltage: 30kV or 80kV
  2. Test frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
  1. Maximum load capacity: 1.1μF@0.1Hz
                          2.2μF@0.05Hz
                          5.5μ[email protected]
  1. Measurement accuracy: 3%.
  2. Voltage peak value error: ≤3%.
  3. Voltage waveform distortion: ≤5%.
  4. Working environment: indoor or outdoor; -10ºC-+40ºC; 85%RH
  5. Fuse: 8A (30kV), 20A(80kV)
  6. Power supply: 220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW, frequency 50Hz, voltage 220V±5%.)
  7. Capacitance of the tested object shall not exceed the max. rated capacitance of the instrument. The max. capacitance please see below table.
 
Model Rated voltage Load capacitance Power fuse Structure & Weight
VLF-34/1.1 30kV 
(peak value)
0.1Hz, ≤1.1µF 8A One piece: 30kg
0.05Hz, ≤2.2µF
0.02Hz, ≤5.5µF
VLF-84/0.5 80kV 
(peak value)
0.1Hz, ≤1.1µF 20A Control unit: 4kg
Booster: 50kg
0.05Hz, ≤2.2µF
0.02Hz, ≤5.5µF


VLF-34 AC Hipot Test Set 30kV VLF Test SetVLF-34 AC Hipot Test Set 30kV VLF Test SetVLF-34 AC Hipot Test Set 30kV VLF Test SetVLF-34 AC Hipot Test Set 30kV VLF Test SetVLF-34 AC Hipot Test Set 30kV VLF Test Set







 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the peak voltage output?
The VLF-34 model offers a peak voltage of 30kV, while the VLF-84 model provides 80kV.
What test frequencies are available?
The device supports selectable test frequencies of 0.1Hz, 0.05Hz, and 0.02Hz.
What is the warranty period?
The product comes with a 1-year warranty.
What types of equipment can be tested?
It is suitable for testing electrical equipment with large capacitance, such as power cables, capacitors, motors, and generators.
Is the device portable?
Yes, it features a trolley-style design with small size and light weight for easy transportation and outdoor use.
What are the payment terms?
Payment terms include LC (Letter of Credit) and T/T (Telegraphic Transfer).
What is the lead time for delivery?
The average lead time is one month for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now