Basic Info.

Model NO.
GDZG-500 120/2
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Output voltage
120kV
Output current
2 mA
Accuracy
1%* full range +1 digitals
Output power consumption
240W
Charging current
7.5mA
Ripple coefficient
≤0.5%
Transport Package
Standard Export Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
2000set/Year

Product Description

GDZG-500 Series 120kV/2mA Smart DC Hipot Test Set


General Information


GDZG-500 series of DC high voltage tester is testing DC high voltage for zinc oxide lighting arrester, magnetic blowing arrester, power cables, generators, transformers, switches and other equipments, which is suitable for electric power branch, power department of factories, scientific research units, railway, chemical industry, power plants.

GDZG-500 series Intelligent DC high voltage generator, using AIPWM technology, the inaccurate linearity of PWM technology is adjusted, so that the accuracy of the instrument has been greatly improved. And adopt AI technology to set the overvoltage protection and overcurrent protection instead of the digital dial switch can only set the voltage value, can not set the current value and voltage drift problem, on the basis of maintaining the manual 0.75UDC1mA function button, increased AI automatic zinc oxide surge arrester measurement, cable section withstand voltage test, automatic withstand voltage test function, and can directly print the test report and save the test report, avoiding the error of the test report handwriting (stored data can only start from 002) , The manual mode is retained, and the printing function under any voltage and current is added, as well as the total time T1 and split-time T2 functions. The instrument adds perpetual calendar and time functions, and the experiment report has time and date.


Features

 
  1. Use large LCD screen, the operation is more user-friendly, can display voltage and current in real time.
  2. Fully automatic test function of zinc oxide arrester, with printing function; accuracy ≤1%, ripple coefficient: ≤0.5%. keep manual 0.75UDC / 1mA. Function.
  3. With large voltage feedback, the output voltage stability is high and the ripple coefficient is ≤ 0.5%.
  4. Segment withstand voltage: The segment voltage and the measurement time of each segment voltage can be set according to the user to complete the automatic boost (automatic cable test).
  5. Single voltage: set a test voltage value, the instrument can automatically rise to this voltage (transformer automatic test).
  6. Micro-ammeter wireless transmission function: it can realize the wireless transmission of high-voltage current data to make the measurement data more accurate and reliable; it can improve the personal safety of the operator. (Optional)
  7. Voltage and current digital protection. It solves the problem that the digital dial switch can only set the voltage value, but cannot set the current value and voltage drift, and the error is ≤1%.
  8. With perpetual calendar, time, storage, printing and other functions.
  9. Earth protection alarm function: If there is no earth connection or poor earth connection, a "wiring fault" will appear and an alarm will be given.


Specifications
 
Output voltage 120kV
Output current 2mA
Output power consumption 240W
Charging current 7.5mA
Control unit box weight 13kg
HV Booster weight 4kg
HV Booster Dimension Ф110
530mm
Voltage measurement error   1.0%*full range ±1 digital  
  Current measurement error   1.0%*full range ±1 digital  
  Overvoltage setting error   AI technology sets overvoltage protection and overcurrent protection. Error ≤1.0%  
  0.75 switching error   High precision 0.75UDC-1mA one-touch button (accuracy≤0.5%) , most suitable for zinc oxide arrester test  
  Ripple coefficient   ≤0.5%  
  Power supply   AC220V, 50/60Hz  
  Ripple factor   ≤0.5%  
  Working mode   Intermittent use: rated load for 30 minutes
1.1 times rated voltage use: 10 minutes
 
Working environment   Temperature: -10ºC~ +40ºC  
  Relative humidity: no more than 85% at room temperature of 25ºC(no condensation)  
  Altitude: below 1500 meters  
  With capacitive load   the capacity of the tested product is unlimited  
  Structural features   Electrically insulated voltage doubler  
  Air insulation, no leakage  

Automatic DC Hipot Tester 120kV/2mA
Automatic DC Hipot Tester 120kV/2mA
Automatic DC Hipot Tester 120kV/2mA



Automatic DC Hipot Tester 120kV/2mA
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier