Variable Frequency AC inductance resonant test systems For GIS

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • Variable Frequency AC inductance resonant test systems For GIS
  • Variable Frequency AC inductance resonant test systems For GIS
  • Variable Frequency AC inductance resonant test systems For GIS
  • Variable Frequency AC inductance resonant test systems For GIS
  • Variable Frequency AC inductance resonant test systems For GIS
  • Variable Frequency AC inductance resonant test systems For GIS
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
GDTF-160/160
power supply
Single phase 380V
Rated Capacity
160kVA
Rated voltage
160kV
Rated current
1A
Working frequency
30-300Hz
Accuracy
1.5% (RMS)
Output waveform
sine wave
Transport Package
Standard Export Package
Specification
ISO, SGS
Trademark
HV HIPOT
Origin
Wuhan China
Production Capacity
2000PCS/Year

Product Description

Variable Frequency AC inductance resonant test systems For GIS
Variable Frequency AC inductance resonant test systems For GIS
Product Description

General information

I. Test Object and Requirement
The system is specially designed for AC withstand voltage test for below items, with below specifications and requirements.
1. 220kV,85000kVA main transformer, capacitance ≤ 0.02μF, test frequency 30-300Hz, test voltage 160kV, test time 1min.
Note: Test objects are only for reference. If you have other spec. test object, please inform us and we will select a suitable GDTF model.
 
Working Environment
Environmental temperature: -15ºC to 45ºC
Related humidity: ≤ 90% RH
Altitude: ≤ 3km
 
Technical Data
Rated capacity: 160kVA
Input power supply: Single phase 220V/Three phase 380V, 50Hz
Rated voltage: 160kV
Rated current: 1A
Working Frequency: 30-300Hz
Output waveform: sine wave
Waveform distortion rate: ≤1%
Working time: constant working of 60mins under rated load. Working of 1min, under 1.1
times of rated voltage
Temperature rise: ≤65K after constant working of 60mins under rated load
Quality factor: Q ≥30 (f=45Hz)
Protective function: Over-current, over-voltage and flashover protections for test object.
Accuracy: 1.5% (RMS)
Applied standard
GB10229-88                          Reactor
GB1094                                 Power transformers
GB50150-2006                      Standard for hand-over test of electric equipment installation engineering
DL/T 596-1996                      Preventive test regulation of electric equipment
GB1094.1-GB1094.6-96              Protection class of Shell
GB2900                                  Electrotechnical terminology
GB/T16927.1~2-1997             High voltage Testing Technique
 
Capacity Determination of the equipment
4pcs Reactors will be designed, each reactor is 40kVA/40kV/1A/100H.
The system 160kVA/160kV will be selected.
The reactors used in series or parallel meets the testing requirements.

Reactors

Test object
Reactors
40kVA/40kV 4pcs
Output voltage of exciting transformer 
Meet 100MVA/110kV transformer (test voltage 160kV, test time 1min) 4pcs reactors in parallel 10kV
Meet 110kV substation system (test voltage 265kV, test time 1min) 4pcs reactors in series 10KV
 Parameters for Individual Parts

1. Exciting Transformer GDJL-10kVA/2.5/5/10kV (1 set)
 
  1. Rated capacity: 10kVA
  2. Input voltage: 0-400V, single phase
  3. Output voltage: 10kV,10KV is used for the 110kV substation system to communicate with pressure resistance.
  4. Type: Dry type
  5. Weight: approx. 65kg

2. Variable frequency power supply GDTF -10kW/220/380V (1 set)
 
  1. Rated power: 10KVA
  2. Working power supply: Single/Three phase 220/380V±10%, 45~65HZ
  3. Output voltage: 0-400V, single phase
  4. Frequency adjusting range: 30-300Hz
  5. Frequency adjusting resolution: ≤0.1Hz
  6. Frequency stability: ≤0.02%
  7. Output current:0~25A
  8. Weight: approx. 15kg.

It can realize below functions,
  1. The Variable frequency power supply can be placed in lengthways and in horizontal, suitable for on-site operation.

b. High stability and reliability. With robust aluminum case and damping rubber support leg, easy for transportation.

c. Touch screen LCD display, or external mouse can be connected.
It shows below parameters,
Resonance voltage(target voltage), test frequency, measurement frequency, LV voltage, LV current, Withstand voltage time, over-voltage and over-current protection, flashover protection, voltage boosting and timing, operation mode switching, capacitance/inductance/frequency calculation, parameter query, frequency curve and voltage curve.

d. Parameters setting and selection
Starting frequency, end frequency, starting voltage, voltage boosting and timing, voltage divider ratio measurement, exciting transformer ratio, over-voltage and over-current protection, flashover protection, test mode, capacitance/inductance/frequency calculation, prompt, and help.

e. Test mode: touch screen/external mouse operation, Auto/Semi-auto/Manual and other modes selection.

f. Protection function and information tips
HV over-voltage protection, LV over-current, over-current protection and Non-resonance protection, zero and flashover protection, emergency stop, low voltage protection.

g. Data storage function: Test result save (manual save), print, upload, and return.
1) 50pcs test results can be saved.
  1. The saved data can be showed on the screen. With USB port, data can be output to print or printed directly by the equipment. (If buyer need this requirement, please specify it on the contract.)

h. Auto stabilivolt function. Voltage stability up to 1.0%.

i. Frequency adjusting range and resolution can be set.
Frequency adjusting range can be set at 30-300Hz, 45-100Hz, 200-300Hz as requirements.
Frequency resolution can be set at 0.1Hz, 0.2Hz, 0.5Hz, or 1.0Hz. Obtain optimized balance between efficiency and accuracy of harmonic adjusting.

j. Coarse tuning and fine tuning for frequency. Search resonance point automatically.

3. HV Reactor GDDK-40kVA/40kV (4pcs)
 
  1. Rated capacity: 40kVA
  2. Rated voltage: 40kV
  3. Rated current: 1A
  4. Inductance: 100H (per set)
  5. Working time: continuous 60min
  6. Temperature rise:<60°
  7. Power frequency:30-300HZ
  8. Type: Dry type
  9. Weight: approx. 42kg

4. Capacitive Divider GDFR-160kV/750pF (1 set)
 
  1. Rated voltage: 160kV
  2. Capacitance: 750pF
  3. Working frequency:30~300Hz
  4. Dielectric loss: tgσ ≤0.5%
  5. Measuring accuracy: 1.5%
  6. Rated voltage:160kV/750pF
Product included
No. Name Module No. & Specs Quantity
1 Exciting Transformer GDJL-10kVA/2.5/5/10kV 1 set
2 Variable frequency power supply  GDTF -10kW/220/380V 1 set
3 HV Reactor GDDK-40kVA/40kV  4 pcs
4 Capacitive Divider GDFR-160kV/750pF 1 set
5 Connecting Cable   1 set
6 Factory Test Report   1 copy
7 User's Guide   1 copy
Company Profile

Variable Frequency AC inductance resonant test systems For GIS

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier