HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
  • HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
  • HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
  • HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
  • HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
  • HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
Find Similar Products

Basic Info.

Model NO.
GDPT-103C
Model number
GDPT-103C
Accuracy
class 0.05
Working range
80%-120%
Working range of tested CVT
1.0, 0.5, 0.2, 0.1
Admittance measurement value
≤ 5.0%
Measurement range
0.000mS-200.0mS
Delivery time
30 days
Transport Package
Plywood Case
Specification
ISO, SGS
Trademark
HVHIPOT
Origin
Wuhan China
HS Code
9030849000
Production Capacity
2000PCS/Year

Product Description

HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C

HVHIPOT On Site CVT Analyzer Calibrator GDPT-103C


Product Description

GDPT-103C CVT On-site Calibrator is designed for analyzing and Calibrate CVT for on-site test.


Features
 
  1. No need for boosting source, standard transformer, load box, and the principle of extrapolation of voltage transformer load curve, single instrument can make on-site test GIS electromagnetic voltage transformer (PT) and capacitive voltage transformer (CVT) 20%, 50%, 80%, 100%, 120% of the ratio and angular difference at full load and light load. The test results fully meet the national transformer verification procedures.
  2.  The measurement of GIS electromagnetic voltage transformer (PT) and capacitive voltage transformer (CVT) error (ratio difference, angular difference) can be completed by a single tester. At the same time, it can measure the capacitance division ratio, the voltage dividing capacitance, the intermediate PT ratio, the intermediate voltage, and the DC resistance of the CVT.
  3.  With polarity, ratio, wiring check function.
  4.  Complete all tests at one time to improve work efficiency, avoid damage to people and instruments caused by operational errors, and ensure safety.
  5.  It has the characteristics of fast test speed, large amount of processing information and large storage capacity (can store millions of data). The memory is 16G and can store millions of data.
  6.  The tester adopts frequency conversion technology and digital processing, and has strong anti-interference ability on site.
  7.  The maximum voltage during the test process does not exceed 4KV, and various protective measures are taken to ensure personal safety and equipment safety and reliability.
  8.  The test process is simple to operate.
  9.  The instrument adopts WINCE system, humanized color touch screen operation, and can also operate the instrument with mouse. The man-machine interface is intuitive and convenient.
  10.  The instrument has dual USB communication port, which can import the internal data of the instrument into the U disk, which is very convenient for on-site data management. The instrument can also be operated using the mouse.
  11.  The wiring diagram inside the instrument is simple and intuitive. The use of the control wiring on site can ensure the correct completion of the test wiring at one time and reduce the preparation time.
Main parameters
 

Under test transformer type

Electromagnetic, capacitance-voltage transformer

Test range of turns ratio


6kV / 100V, 6kV/√3/ 100V/√3

10kV / 100V, 10kV/√3/ 100V/√3

35kV / 100V, 35kV/√3/ 100V/√3

110kV /100V, 110kV/√3/100V/√3
220 / 100V,220kV/√3/100V/√3
Accuracy:0.02%

Error measurement accuracy

0.05%

Partial pressure ratio measurement accuracy

0.5%

Partial capacitance measurement accuracy

2%

DC resistance measurement accuracy

0~0.1Ω 3%
0.1~50Ω 1%

Working environment

temperature:5ºC~40ºC , humidity:<80%(25ºC)

Altitude:<2500m, power frequency:50±0.5Hz

Verification part

voltage range: 0~100V (percentage error 0.5%)
              Ratio difference: 0.001%~3% (100V)
              Angle difference: 0.00'~50' (100V)
              Error: *X=±(2%×X+2%×Y±2 words)
                    *Y=±(2%×X+2%×Y±2 words)
              Admittance: 0.1ms~99.9ms
              Error: *X=±(2%×X+2%×Y±2 words)
                    *Y=±(2%×X+2%×Y±2 words)

Dimension

496*394*185 mm

Weight

About 14kg



HVHIPOT On Site CVT Analyzer Calibrator GDPT-103CHVHIPOT On Site CVT Analyzer Calibrator GDPT-103CHVHIPOT On Site CVT Analyzer Calibrator GDPT-103CHVHIPOT On Site CVT Analyzer Calibrator GDPT-103CHVHIPOT On Site CVT Analyzer Calibrator GDPT-103C
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier