HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • NDIR Technology: Uses non-dispersive infrared analysis for accurate SF6 leakage detection without radioactive risk.
  • Fast Response: Data stabilizes within 10 seconds with fast test speed and good repeatability.
  • Portable Design: Ultra-lightweight ABS structure, weighing about 2kg, with built-in lithium battery for 6 hours continuous use.
  • Data Storage: Stores more than 100 groups of test data based on gas concentration and test time for easy query.
  • Durable Sensor: Non-contact measurement prevents sensor poisoning; no need for regular sensor or argon gas replacement.
  • OLED Display: 3.5-inch OLED screen provides clear visibility even in strong sunlight.
  • Customizable Pipelines: Pipelines can be customized as per request to suit specific testing requirements.

Product Images of HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer

HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer pictures & photos
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer pictures & photos
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer pictures & photos
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer pictures & photos
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer pictures & photos
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer pictures & photos
HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
    HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
    HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
    HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
    HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
    HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
  • HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
    HVHIPOT GDWG-III  insulation gas SF6 Gas Leak Detection Device SF6 Analyzer

Find Similar Products

Product Description

Portable SF6 Leakage Tester SF6 Gas Leak Detection Device SF6 Analysis (GDWG-III)

General introduction

GDWG-III SF6 gas leakage detector, with non-dispersed infrared (NDIR) technology, is mainly used to pinpoint and measure SF6 leakage on GIS and refilling equipment within power industry.
The annual leakage rate of SF6 gas electrical equipment is measured with bandaging method. At the same time, the equipment is widely used in power supply bureau, substations, high voltage switch company, laboratory hood and scientific test. 

Application
  • High voltage switch-gear
  • Helicopter rotor blades
  • Gas transmission system
  • Fire extinguisher
  • Ventilation rate study
  • Hazardous material
  • Tank
Advantages
  • No radioactive risk.
  • No need to replace high purity argon gas regularly.
  • No need to replace sensor regularly, cost-effective.
  • No need to make linear calibration every year, no wearing parts.
  • Not effected by humidity, environment pollution or data drift.
  • When there is severe leakage or SF6 gas concentration is up to 100%, it will not be polluted or damaged.


Features
  • To measure SF6 gas leakage qualitatively and quantitatively.
  • To locate SF6 gas leakage point.

  • Parameters like SF6 gas concentration, temperature, humidity, power indicator, date and diaphragm pump status are displayed.

  • User-friendly interface.

  • Use NDIR technology and advanced sensor from Germany.

  • Fast test speed and good repeatability, data is stabilized within 10s.

  • With temperature and pressure compensation.

  • No false alarm, no gas except SF6 responses.

  • Non-contact gas measurement ensures that sensor won't be poisoned at any concentration rate.

  • Thermostatic chamber ensures no temperature drift at ambient temperature for sensor.

  • 3.5inch OLED display, legible in the strong sunlight.

  • Built-in lithium battery, standby time is long.

  • Pipelines is customized as per request.

  • Pump suction sampling ensure good sealing of gas path under test.

  • More than 100 groups of test data are stored based on gas concentration and test time, easy to query.

  • The outer casing is high strength, fully shielded, ultra-lightweight ABS material structure.



Specifications

Measuring principle

Non-dispersive infrared sensor (NDIR)

Measuring range

0-1500ppm SF6

Resolution

0.1ppmv

Accuracy

±2%FS (0-1000ppm)

Repeat-ability error

≤±1%

Sensitivity

1ppmv

Response time

≤10s

Recovery time

≤15s

Stability

≤±20ppm, more than 1000 hours

Sampling mode

Pump suction type, flow up to 1L/min.

Zero drift

≤±1%(F.S/year)

Linear error

≤±1%

Peak current

<700mA

Average power

<2W

Operation air pressure

800-1150hPa

Environment humidity

0-95%RH

Storage temperature

-20 ~ +60ºC

Operation temperature

-20 ~ +50ºC

Operation humidity

0-95%(non-condensing)

Working voltage

220VAC±10%,50Hz Or Built-in Li-battery, continuous working 6 hours after full charge.

Dimension

220*250*120mm

Weight

About 2kg


Accessories
 
Main unit 1 set
Charger 1 piece
Hand-held probe 1 piece
Anti-slip belt 1 piece
Hose 600 mm 1 piece
User's guide 1 copy
Warranty card 1 copy


HVHIPOT GDWG-III insulation gas SF6 Gas Leak Detection Device SF6 AnalyzerHVHIPOT GDWG-III insulation gas SF6 Gas Leak Detection Device SF6 AnalyzerHVHIPOT GDWG-III insulation gas SF6 Gas Leak Detection Device SF6 AnalyzerHVHIPOT GDWG-III insulation gas SF6 Gas Leak Detection Device SF6 Analyzer
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What technology does the GDWG-III use for SF6 detection?
It uses Non-Dispersive Infrared (NDIR) technology with advanced sensors from Germany for accurate and safe detection.
Is the device portable and battery-powered?
Yes, it weighs about 2kg and features a built-in lithium battery that allows for 6 hours of continuous working time after a full charge.
What is the warranty period for this device?
The device comes with a 1-year warranty.
Can the pipelines be customized?
Yes, the pipelines are customized as per request to meet specific user needs.
Does the device require regular maintenance or calibration?
No, it does not need regular replacement of high purity argon gas or sensors, and no linear calibration is required every year.
How many groups of data can the device store?
It can store more than 100 groups of test data based on gas concentration and test time for easy query.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now