Basic Info.

Model NO.
GDSF-413CPD
Gas
SF6
Type
Electrochemical Gas Analyzer
Power supply
220V AC ±10%, 50Hz
Use environment temperature
-20~+60 centigrade
Environment humidity
90%RH
Weight
about 5kg
Resolution
0.01PPmv
Gas flow rate
400 ~ 600ml/min
Flow rate display
0~1000mL imported digital flowmeter
Transport Package
Export Wooden Box
Specification
395*295*155mm
Trademark
HV HIPOT
Origin
China
HS Code
9031809090
Production Capacity
1000set/Year

Product Description

GDSF-413CPD SF6 Gas Comprehensive Tester
HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester

GDSF-413CPD type SF6 gas comprehensive tester is a portable instrument developed by our company for on-site testing of SF6 gas trace moisture content, SF6 gas purity and SF6 gas decomposition products. It's core device adopts the most advanced Stirling principle cold mirror technology in the industry to test the moisture content. The infrared principle SF6 gas purity test and the CF4 gas sensor produced by the European sensor company are used to test the purity of SF6 gas and the trace CF4 gas content.The electrochemical sensor produced by the Swiss Mambabo Company is used as the sensor element for the test of SF6 gas decomposition products. With the professional hardware chip and excellent software algorithm of STMicroelectronics, we have produced a new generation of gas trace moisture tester.
GDSF-413CPD SF6 comprehensive tester provides users with reasonable and efficient SF6 gas analysis methods. The instrument design is beautiful and reasonable, and the instrument material is excellent. The overall design is a combined plan. The transportation and carrying solution is compatible with our company's full range of SF6 gas analysis equipment. This product is suitable for on-site use in any natural environment.

Application

Analysis of trace moisture, purity and decomposition products of SF6 gas electrical equipment for electric power
SF6 gas cylinder gas quality test
Quality test of SF6 gas for recovery and reuse
High purity gas manufacturing
Semiconductor industry dry gas supply
Research and development use
Clean room/dry house monitoring
Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases.

Features

  1. With self-calibration function, ensure the stability and reliability of moisture, purity and decomposition detection data throughout the year.
  2. Fully imported high-precision sensors, with self-checking function, to ensure that the detection data of moisture, purity and decomposition products are stable and reliable throughout the year.
  3. Full-channel polymer material design, the devices use Legris, Kangmosheng, Swagelok products, to ensure that there is no wall phenomenon, to ensure the test speed.
  4. The oil-free stainless steel body control valve is used to ensure the accuracy of the detection value.
  5.  Advanced software algorithms improve the testing accuracy of imported sensors.
  6. Combined chassis configuration scheme, users can easily combine related instruments and accessories. Realize the overall packaging and carrying, so that users have a more relaxed experience.
  7. The test can be carried out after starting up, without the shaking process.
  8. Temperature conversion and pressure data correction.
  9. Fuzzy computing technology.
  10. The high-power lithium battery power system can realize AC and DC dual power supply. No on-site AC power is required. Lithium battery can work continuously for more than 8 hours without external power supply.
  11. Anti-electromagnetic interference circuit design to ensure product reliability.
  12. Can expand USB communication, serial communication, wireless communication module, can realize upper computer communication and printing function. (Optional)
  13. Large-capacity memory, can realize the storage function of 1000 groups of data.
  14. The gas path pretreatment function can clean the test pipeline before field test work, shortening the test time. (Optional)
  15. The instrument has a test gas recovery function, which can recover sulfur hexafluoride measuring gas. Protect the natural environment. (Optional)
  16. The test data is stable, and the standard dew point value and the converted dew point value under the condition of 20 ºC can be provided at the same time.
  17. The purity measurement has a measurement accuracy of 0.5% of the full scale, which can be applied to the measurement of high-concentration SF6 gas, and can also be used for the measurement of 70% SF6 gas.
  18. The best test flow area is displayed, and the user can adjust the gas flow intuitively and quickly. Shorten the test time.
  19. The air inlet adopts a miniature self-sealing joint design, and the tested gas path will not leak when the gas path is disconnected.


Specifications
 

SF6 Humidity

  1. Measurement method: Chilled mirror measurement principle (Stirling technology)
  2. Use environment temperature: -20ºC ~ +60ºC
  3. Measurement range: -65ºC ~ +20ºC (single point dew point acquisition 90 seconds)
  4. Measurement error: better than ±0.2ºC
  5. Repeatability error: ±0.1ºC
  6. Resolution: 0.01ºC
  7. Display unit: ºC, ppm, ºCP20 (with the conversion value of the dew point of the environment 20ºC)

SF6 Purity

  1. Measurement method: Infrared Measurement Principle (NDIR series sensors)
  2. Use environment temperature: -20ºC ~ +60ºC
  3. Measurement range: 0~100%
  4. Response time [90%] 60s
  5. Measurement error: better than ±0.3%FS
  6. Repeatability error: ±0.3%
  7. Resolution: 0.01%
  8. Display unit:%
CF4 Gas
  1. Measurement method: Infrared Measurement Principle (NDIR series sensors)
  2. Use environment temperature: -20ºC ~ +60ºC
  3. Measurement range: 1000PPmv
  4. Response time [90%] 10s
  5. Measurement error: better than ±0.3%FS
  6. Repeatability error: ±5PPmv (small range customization can be drunk ±0.5PPmv)
  7. Resolution: 0.1PPmv
  8. Display unit: PPmv

SF6 Decomposition Products

  1. Measurement method: Electrochemical Measurements Principle (Electrochemical series sensors)
  2. Use environment temperature: -20ºC ~ +60ºC
  3. Measurement range: H2S: 0 ~ 200ppmv
  4. SO2: 0 ~ 200ppmv
                                            CO: 0~500PPmv
                                            HF: 0~50PPmv
                                            H2: 0~2000PPmv
                                            AIR(O2): 0~0.1%
  5. Accuracy: SO2:  <10PPmv ±0.5PPmv; >10PPmv ±5%
  6.                        H2S: <10PPmv  ±0.5PPmv;>10PPmv   ±5%
                           CO: <50PPmv  ±2PPmv;>50PPmv  ±4%
                           HF <10PPmv ±0.5PPmv;>10PPmv   ±5%
                           H2 ≤200μL/L, ≤±10.0μL/L;>200μL/L ≤±5%
                             AIR(O2) ±4%FS
  7. Repeatability:  SO2 <10PPmv ±0.2PPmv
  8.                                       >10PPmv   ±2%
                                  H2S <10PPmv ±0.2PPmv
                                        >10PPmv ±2%
                                  CO <50PPmv  ±2PPmv
                                       >50PPmv ±2%
                                  HF <10PPmv  ±0.2PPmv
                                       >10PPmv  ±2%
                                  H2 <10PPmv   ±0.2PPmv
                                       >10PPmv  ±2%
                                  AIR(O2)  ±2%
  9. Resolution: 0.01PPmv
  10. Display unit: PPmv
  11. Gas flow rate: 400 ~ 600ml/min
  12. Flow rate display: 0~1000mL imported digital flowmeter
  13. Sample gas pressure: ≤1MPa
  14. Environmental humidity: 90%RH
  15. Influence of measurement value: no influence on pressure and flow
  16. Power supply:220V AC ±10%, 50Hz, AC/DC use, over-charge protection, continuous working is no lower than 8hours.
  17. Dimensions: 395×295×155 (mm)
  18. Weight: 2kg
 

Accessories

Main Tester                                                                                    1 piece
Connectors                                                                                     1 set
Pipe (include flow adjustment valve and fast connector)     1 set
Tail pipe                                                                                          1 set
Spare parts                                                                                    1 set
Charger                                                                                          1 piece
User's Guide                                                                                  1 piece
Test Report                                                                                    1 piece

HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester
HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester
HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester
HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester
HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester
HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester



HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester

HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester


HVHIPOT GDSF-413CPD SF6 Gas Comprehensive Tester


 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier