GDYT-30/100 Partial Discharge Test System is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It is widely used in electrical manufacturing, power operation departments, research institutes and universities.
The system includes:
1. Automatic Hipot Test Control Table GDYT-30/100
2. PD-free Gas type transformer YDQW-30/100
3. Coupling capacitor TAWF-100kV
4. Protective resistor GR100kV
5. Isolation filter LBQ-30kVA
6. Partial discharge detector
System specification |
|
Power supply |
380V±10%, 60HZ |
Rated capacity |
30kVA |
Output voltage |
100kV |
Output current |
300mA |
Short-circuit impedance |
<18% |
Operation time |
30mins@100% rated voltage and current. Continuous working@ 2/3 rated voltage and current. |
Wave form distortion rate |
<3% when voltage regulator input voltage distortion rate <3%. |
PD value |
≤5pC @ 100% rated voltage |
Control unit |
|
Power |
AC380V±10%, 60Hz |
Capacity |
30kVA |
Output voltage |
AC 0-430V |
Rated output current |
75A |
HV voltmeter range |
0-100kV |
Timing range |
0-999s |
Voltage and current accuracy |
≤1.5%(F.S)±2digits |
Environment temperature |
-20ºC to 50ºC |
PD-free Gas testing transformer (HV unit) |
|
Rated capacity |
30kVA |
Input voltage |
0-400V |
Input current |
AC 0-75A |
Output voltage |
AC 0-100kV |
Output current |
AC 300mA |
Voltage accuracy |
AC 1.5% |
PC value on rated voltage |
≤5pc |
Voltage distortion factor |
<3% |
Insulation dielectric |
SF6 gas |
Coupling capacitor |
|
Rated frequency |
60Hz |
Standard capacitance |
600pF±10% |
Rated voltage |
100kV |
Voltage ratio |
1000/1 |
Dielectric loss |
<0.5% |
Measurement accuracy |
1% |
Permitted operation time |
Same with testing transformer |
PD value |
≤5pc on 100% of rated voltage, ≤3pc on 80% of rated voltage. |
Protective resistor |
|
Rated frequency |
60Hz |
Rated voltage |
100kV |
Resistance |
7kΩ |
Rated current |
0.3A |
Permitted operation time |
Same with testing transformer |
Isolation filter LBQ-30kVA |
|
Rated capacity |
30kVA |
Rated voltage |
400V |
Rated current |
75A |
Frequency |
60Hz |
Attenuation |
40kHz-100kHz ≥40dB 100kHz-1.5Mhz ≥60dB |
Permitted operation time |
Same with testing transformer |
With L-C filter loop circuit, and built-in filter compensation device. |