HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System
  • HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System
  • HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System
  • HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System
  • HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System
  • HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System
Find Similar Products

Basic Info.

Model NO.
GDBT-5000kVA/35kV
Transport Package
Plywood Case
Specification
ISO
Trademark
HVHIPOT
Origin
Wuhan, China

Product Description

I. General information

GDBT-5000kVA/35kV is mainly to make no-load and load test, power frequency withstand voltage test and DC resistance test for 35kV, 5000kVA and below distribution transformers.


II. Test Items
 
  1. 3-phase voltage RMS
  2. 3-phase current RMS
  3. 3-phase active loss
  4. 3-phase reactive loss
  5. 3-phase average voltage
  6. 3-phase voltage average value
  7. 3-phase current average value
  8. Total power
  9. No-load current percentage
  10. Impedance voltage percentage
  11. Frequency
  12. Power factor
  13. Power frequency withstand voltage test
  14. DC resistance measurement
  15. Turns ratio measurement
  16. Induced voltage test


III. Panel Instruction of test bench


 
  1. LCD screen (PC screen)                  
  2. Power Analyzer
  3. Output voltmeter of power frequency withstand voltage test
  4. Output current meter of power frequency withstand voltage test
  5. Assistant LCD display, when making power frequency withstand voltage test, using this LCD display to operate.
  6. Power indicator light switch
  7. Emergency stop button
  8. Control mode selection (Manual/Automatic)
  9. Power switch

   
IV. Software operation
  1. Software interface introduction
After power on the test bench, open the software icon to enter the main page of the system as shown in the following figure, including system setting, test product information, system status display, real-time test data, experimental operation area, etc
  1. Main menus and submenus
The top part displays 6 main menus in order: Tested product information, Communication setting, Program setting, Test report, Alarm information, Test completion function menu, as shown in the figure below:

2.1 Test product management menu

[Equipment] The menu is mainly used to build the information of tested transformer, select the previous record file, or exit the software. Click this menu system to pop up, as follows,



[Equipment] can be selected as: transformer, reactor, switchgear.

Click [Add]
Pop-up bullet box is used to set some of the main parameters of the tested transformer, mainly transformer nameplate parameters. According to the above parameters, a pull-down arrow indicates an alternative for choice.



Setting method:
 
  1. Serial Number: Input the serial number of tested transformers.
  2. Type: Basic model of transformer, such as S11, S13, etc.
  3. Rated power: the capacity of the transformer, such as 400kVA.
  4. HV Rated V(V): the high voltage side rated voltage of the transformer.
  5. LV Rated V (V): the low voltage side rated voltage of the transformer.
  6. HV Rated I (A): The high voltage side rated current of the transformer
will be automatically calculated by the rated capacity and the high voltage side rated voltage.
  1. LV Rated I (A): The low voltage side rated current of the transformer
will be automatically calculated by the rated capacity and the low voltage side rated voltage.
  1. Equipment type: select the transformer type, such as oil-immersion
transformer, etc.
  1. Phase: Single phase or three phase can be selected.
  2.  Connection Symbol: Select the connection of tested transformer.
  3.  Short circuit impedance: transformer short circuit impedance, input
number, no %.
  1.  Copper/Aluminum: cooper and aluminum coefficient, such as: copper 235.
13) Reference temperature: the selection window can be pulled down, such as 75ºC.
14) Tapping range: such as Tap 5, 2.5 voltage regulation ratio is ± 2 * 2.5%.
15) Structure type: the selection window can be pulled down, such as: oil immersion.
16) Cooling mode: can be pulled down the window for selection, such as: ONAN.
17) Test completed: you can pull down the window for selection, such as: to be checked.

[Delete] Available to delete the selected useless number.

[Modify] Modify the parameters corresponding to the incorrect setting mark.

[Report] Query the selected number report.

[Device number / Information number] You can also find it according to the label number, and then view the parameters or reports.

HVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test SystemHVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test SystemHVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test SystemHVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test SystemHVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test SystemHVHIPOT GDBT-5000kVA 35kV Transformer Test System Load No Load Test System