HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price

Product Details
Customization: Available
Type: Universal Testing Machine
Accuracy Grade: 0.5
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
  • HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
  • HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
  • HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
  • HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
  • HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
Find Similar Products

Basic Info.

Model NO.
GDJB-61850
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
5kg
Power Source
AC220V
Model number
GDJB-61850
Power supply
AC 220V, 50Hz; DC 110V/220V
Binary outpt contact
4 pair, idle contact
Output capacity
250V(AC/DC)/0.5A
Relay actuation time
< 3ms
Binary input contact
Quantity: 8 pair, 20~250V(DC) or idle contact
Sampling frequancy
10kHz
Analog small signal input
Channel:12
Delivery time
40 days
Dimension
256mm*182mm*365mm
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030899090
Production Capacity
1000 Sets/Year

Product Description

IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price

HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price



Product Description

GDJB-61850 Optical Digital Relay Protection Test System adopts embedded real time Embedded operating 
system high  performance  Power PC, large scale FPGA and other technologies, combines with field condition 
of the electric power and the  experience from many power users, and then independently researched and 
developed this new portable  product. GDJB-61850 provides complete testing plan for digital protection & 
automation device and instrument under IEC61850, IEC60044 
standard protocol system, it is widely used in 
smart substation, Electrical Power Research Institute, original equipment manufacture and other R&D 
institution.


Features
  • Sending, receiving and powerful computational analysis ability of multiple messages.
  • Perfect engineering test management plan.
  • Special automatic test template.
  • Standard, open test model and interface.
  • Support for multiple cascading tests.

Specifications
 
Power supply AC 220V, allowable variation: -20%~15%; frequency: 50Hz, allowable variation: -4%~2%; waveform: sine wave
DC 110V/220V, allowable variation: -20%~15%; ripple coefficient<5%;







Interface

Ethernet communication
Model: 10/100Base-Tx;
Port: 2 pcs;
Interface type: RJ45;

Fiber optic Ethernet
Model: 100Base-FX/1000Base-FX;
Port: 8 pair;
Interface type : LC;

FT3 optical fiber serial port
Adopted standard: IEC60044-7/8;
Port: 6pcs for sending, 1pcs for receiving;
Interface type : ST;
Synchronous interface Interface type : ST;
Timing deviation: < ±1μs;

Cascading synchronization interface
Port: 1-way for B code,1-way for RS485
(adaptive master slave mode, can input, output);
Interface type: phoenix terminal;

Binary output contact
Quantity: 4 pair;
Type: idle contact;
Output capacity: 250V(AC/DC)/0.5A;
Relay actuation time: < 3ms;



Binary input contact
Quantity: 8 pairs;
Type: 20~250V(DC) or idle contact;
Sampling frequency: 10kHz;
Time resolution: 100μs;
Anti-jitter time: 0~25ms;
Timing error: ±0.1ms(0.001s~1s),±0.01%(1s~1.5x105s);
Max.timing: 1.5x105s;
Analog small signal input Channel:12;
Voltage range: ±10V;
Voltage accuracy: 0.1%;
Max.current: 1mA;
Allowable input frequency: sine signal 10~250Hz, transient signal DC~10.0kHz;
Frequency accuracy: 1mHz;
Frequency resolution: 0.001Hz;
Phase accuracy: < 0.1º;
Status indication: green light means there have signal output;
Interface type: phoenix terminal;
Analog small signal output Channel:12;
Voltage range: ±10V;
Voltage accuracy: 0.1%;
Max.current: 1mA;
Allowable input frequency: sine signal 10~250Hz, transient signal DC~10.0kHz;
Frequency accuracy: 0.002%(1mHz under power frequency);
Frequency resolution: 0.001Hz;
Phase: phase angle range 0~359.9º, accuracy < 0.1º, resolution ±0.01º(50/60Hz);
Interface type: phoenix terminal;
Size (W×H×D): 256mm×182mm×365mm;
Weight 5kg;

HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
HVHIPOT IEC Standards 61850 Optical Digital Relay Protection Tester Factory Price
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier