HV HIPOT Portable Six Phase Relay Protection Tester

Product Details
Customization: Available
After-sales Service: yes
Warranty: 1
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HV HIPOT Portable Six Phase Relay Protection Tester
  • HV HIPOT Portable Six Phase Relay Protection Tester
  • HV HIPOT Portable Six Phase Relay Protection Tester
Find Similar Products

Basic Info.

Model NO.
GDJB-1200A
Power Supply
AC 220V; 50Hz
6-phase AC current output
(L-N) 6*0...30A
3-phase AC current output
(L-N) 3*0...60A
1-phase AC current output
(L-N) 1*0...180A
6-phase DC current output
(L-N) 6*0...10A
3-phase DC current output
(L-N) 3*0...20A
AC voltage output
(RMS) 0~120V
Weight
19KG
Size
480mm*360mm*2000mm
Transport Package
Carton or Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030820000
Production Capacity
2000PCS/Year

Product Description

Factory Price Six-Phase Relay Protection Tester Secondary Injection Test Set

 
Product Description

Relay Protection Microcomputer Test Device plays a key role in operating electricity power systems reliably and safely. It is the testing device used in professional field of microcomputer protection, relay protection, excitation measurement, fault recorder.



Features

1. High-Performance Industrial Control Computer

High performance Industrial control computer is adopted as the controlling computer, by which users can run the windows operating system directly. With 8.5"TFT true color LCD display, tracking ball and optimized keyboard, which can be used without the external mouse and keyboard. USB interface, 10-100M net mouth and serial communication interface are located on the back plate of this tester, by which users can access data, communicate data and upgrade software conveniently.


2. Digital Signal Processor Microcomputer

High-speed digital controlling processor is adopted as the output core of the tester. 32 bit double precision arithmetic is employed in the software, through which arbitrary high-accuracy waveform of each phase can be produced. Since integrative structure is adopted, the structure of the tester is layed compactly.The distance of data transmission is short with tight structure, which overcomes the problem of fewer points of waveform output due to long datacommunication line and narrow frequency band when using the test controller controlled directly by PC.


3. D/A Conversion and Low-Pass Filtering

High precision D/A converter is employed for ensuring the precision and linearity of current and voltage in the whole range.

Due to high density of fitting point, fidelity of waveform is high and harmonic component is small, which doesn't have a strict requirement on the low-pass filter. Consequently, it has good characteristics of transient, phase frequency and amplitude frequency, which is easy to perform accurate phase-shifting and harmonic superposition and ensures very high precision even when the frequency is high.


4. Voltage and Current Amplifier

For phase current and voltage, high performance linear amplifier output mode is used in order to make the current and voltage source to directly output all kinds of waveform from the DC waveform to the waveform including all kinds of frequency components, such as square wave, combined waveform overlapped by each order harmonic, fault transient waveform, etc. In addition, the output waveform is clear and smooth without high-frequency radiated interference with neighboring equipment. It can simulate well all kinds of current and voltage characteristics under the circumstance of short circuit fault.


5. Digital Input and output

This tester has 10 channels digital input and 8 channels output, please refer to the corresponding instruction to hardware structure of 702/703" Tester.

The switching input circuit is compatible for both the empty contacts and 0-250V electric potential contacts in the input and output circuit. When the electric potential contacts are selected, 0-6V belongs to closed switch and 11-250V belongs to open switch. The switching capacity can test the action time and the action time interval of every phaseswitch's contact conveniently.


6. Auxiliary DC Power Supply Output for Special Use

A circuit of special adjustable DC power supply output is located on the rear panel, which has 110V and 220V two shifts that can be used as test standby power supply on the spot. We still set a potentiometer for this power supply, it can be adjusted within the range of 80%-110%. Rated current of this power supply is 1.5A, which can be used as DC power supply of protective tester or switch loop supply. If overload or short circuit occurs, corresponding protector tube will be burned out (2A/250V), uses only need to change this protector tube at that time. 



Specifications
 
AC Current Output
6-phase (RMS)   6*0~30A  
Accuracy ≤0.5A: ±2mA
>0.5A: 0.2%
3-phase (RMS)   3*0~60A
6-phase parallel current output (RMS)    0~180A
Allowable long time working value of phase current (RMS)   10A
Maximum output power of phase current 400VA
Allowable working hours @ max. output of 6-phase parallel current    10s
Frequency range (Fundamental wave)     0~1000Hz
Harmonic times                         1~20 times
DC Current Output
Current output     0~±10A/phase;  0~±60A/6-pahse parallel
Accuracy         0.5%
Maximum output load voltage   20V
AC Voltage Output
Phase voltage output (RMS)   0~120V, accuracy: 0.2%
Line voltage output (RMS)     0~240V
Phase voltage/Line voltage output power   80VA/100VA
Frequency range (Fundamental wave)     0~1000Hz
Harmonic times                         1~20 times
DC Voltage Output
Phase voltage output amplitude   0~±160V, accuracy: 0.5%
Line voltage output amplitude 0~±320V
Phase voltage/Line voltage output power   70VA/140VA
Binary
Binary input      10 channels
Idle contact       1~20mA, 24V
Potential contact access   "0": 0 ~+6V; "1": +11 V ~+250 V
Binary output      8 pairs   DC: 220 V/0.2 A; AC: 220 V/0.5 A
Time Measuring Range 0.1ms~9999s, Measuring accuracy: <0.1mS
Dimension & Weight 480*360*200mm³, 19kg
 

HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester
HV HIPOT Portable Six Phase Relay Protection Tester


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier