HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer

Product Details
Customization: Available
After-sales Service: 1 year
Display: Digital
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer
  • HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer
  • HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer
  • HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer
  • HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer
Find Similar Products

Basic Info.

Model NO.
GDC-9560B
Usage
gas content analyzer of insulation oil
Type
Transformer Tester
Environment
Room Temperature
Warranty
With Warranty
Power Source
AC 85V-265V
Weight
60kg
Installation
Portable Precise
Customized
Customized
Model number
GDC-9560B
Power Supply
AC 220V±10%
Power Frequency
50Hz/60Hz ±1%
Temperature Control Range
room temperature 5-400°C, step 1°C
Temperature Accuracy
±0.1°C
Temperature Increasing Steps
16 steps
Increasing Speed
0.1-40ºC/min
External Event
4 channels
Detector
FID, TCD, ECD(optional), FPD(optional)
Communication Port
Ethernet, IEEE802.3
Transport Package
Plywood Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030849000
Production Capacity
1000 sets/year

Product Description

GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer

Product Description

GDC-9560B Gas Chromatograph Analyzer is to analyze the gas content of insulation oil by gas chromatographic method. It is effective to judge if the running equipment has potential fault like over-heat, discharge or not, to ensure the safety of power grid. It is also necessary to be used for manufacturer of gas/oil equipment to inspect their equipment before leaving factory.

The gas is considered as carrier gas. When sample gas is sent to sample injector,it will enter into packed column or capillary column by carrier gas. As the boiling point, polarity and adsorption coefficient of each components of sample gas are different, the components will be separate, then the detector behind will detect each components in sequence according to physicochemical characteristic. At last, the chromatographic analyzer will record and analyze the chromatogram of each components and get the results.
 

Features
  • 5.7inch color LCD screen, meets the demands of different users.
  • Using advanced 10/100M adaptive Ethernet communication interface, and built-in IP protocol stack, realizing long distance data transmission easily through intranet and internet.
  • Design of 3 independent connection process. It can be connected with local processing(laboratory), more convenient for supervisors to monitor running status and analyze the results.
  • Equipped with network edition workstation, simultaneously support multiple chromatograph working, with data processing and control, which simplifies the document management, and reduce the lab investment cost and running cost.
  • System in English and Chinese, which can be switched freely.
  • Using a multiprocessor parallel working mode, more stable and reliable. It meets complex sample analysis, FID and TCD detector are supplied. Other detector can be optional if necessary.
  • One piece TCD detector and 2pcs FID detectors are supplied, including H2 and O2 are detected by TCD detector, hydrocarbon gas such as methane, ethylene, ethane, acetylene are detected by FID1 detector, CO and CO2 are detected by FID2 detector.
  • Brand-new microcomputer temperature control system,high precision and reliability. 6-channels independent temperature control system, 16steps temperature programmed, broad range sample analysis. It also has automatic door system to improve the LV temperature accuracy and faster temperature speed
  • Modular design, clear and convenient to upgrade system.
  • With timing and self-starting program, easily complete online analysis of gas sample.(It is necessary to select online sample components by users.)
  • Full computer keyboard operation system, simple operation, more convenient. Detectors have automatic identification technology. It also has fault diagnosis and power-off data protection function, automatic memory setting parameters.
  • Built-in low noise, high resolution 24digit AD circuit, and functions of baseline storage/deduction.
  • Suitable for using in WinXP, Win2000, Windows7 operation system. Standard CDF file will be read for sampling data, so it can be integrated with Agilent, Waters chromatographic work station
  • With MODBUS/TCP standard port, easy to connect with DCS.
  • It can be integrated with automatic sampler produced by various manufacturer, such as Shimadzu AOC-20i, HTA HT series liquid/gas sampler.

Specifications
 
Temperature control range room temperature 5-400ºC, step 1ºC, accuracy ±0.1ºC.
Temperature increasing steps  16 steps
Increasing speed 0.1-40ºC/min
Gas control Mechanical valve control mode and electronic pressure flow control mode for option.
External event 4 channels.
Sampler type Packed column, capillary tube, six-way valve gas sampling, automatic headspace sampling for option.
Detector FID, TCD, ECD(optional), FPD(optional)
Start mode Automatic or manual.
Communication port Ethernet, IEEE802.3

FID(flame ionization detector)

Detection limit ≤2×10-11g/s (Hexadecane/isooctane)
Baseline noise ≤5×10-14A
Baseline shift ≤1×10-13A/30min
Linear range ≥ 106
 

TCD(thermal conductivity detector)

Sensitivity S≥2500mV•ml/mg (benzene/methylbenzene) (enlarge 1,2,4,8 times for option)
Baseline noise ≤20μV
Baseline shift ≤30μV/30min
Linear range ≥104
 

ECD (electron capture detector) optional

Detection limit 1×10-13g/ml (Hexachlorocyclohexane/isooctane)
Baseline noise ≤0.03mV
Baseline shift ≤0.2mV/30min
Linear range 103
Radioactive souce 63Ni
 

FPD (flame photometric detector) optional

Detection limit (S)≤5×10-11g/s, (P)≤1×10-12g/s(parathion-methyl/ absolute ethyl alcohol)
Baseline noise ≤3×10-13A
Baseline shift ≤2×10-12A/30min
Linear range Sulphur≥102, phosphorus≥10
 
HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer
HVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas AnalyzerHVHIPOT GDC-9560B Lab Use Oil DGA Dissolved Gas Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier