  • GD6800 HV HIPOT Capacitance and Transformer  Tan Delta Tester
  • GD6800 HV HIPOT Capacitance and Transformer  Tan Delta Tester
  • GD6800 HV HIPOT Capacitance and Transformer  Tan Delta Tester
  • GD6800 HV HIPOT Capacitance and Transformer  Tan Delta Tester
  • GD6800 HV HIPOT Capacitance and Transformer  Tan Delta Tester
  • GD6800 HV HIPOT Capacitance and Transformer  Tan Delta Tester
Find Similar Products

Basic Info.

Model NO.
GD6800
Type
Capacitance Measuring Tester
Environment
Room Temperature
Warranty
With Warranty
Power Source
AC 85V-265V
Weight
〉10Kg
Installation
Direct Connected
Customized
Customized
Anti-interference principle
Frequency conversion method
Working condition
-15degree~40degree, RH<80%
Power supply
AC 220V, Generator can be used.
High voltage output
0.5KV~10KV, Every 0.1kV
Self-excitation power
AC 0V~50V/15A
Dimension
445*345*380mm
Product name
Capacitance and Dissipation Factor Tester Tan Delt
Transport Package
Wooden Box
Specification
ISO9001
Trademark
HV Hipot
Origin
China
Production Capacity
9000 Sets/Year

Product Description

GD6800 Transformer CVT Capacitance and Dissipation Factor Tester

GD6800 HV HIPOT Capacitance and Transformer Tan Delta Tester

 

Product Description

GD6800 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.

Features

Touch LCD screen display.
Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
The instrument data can be exported through U disk.
Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
LCR automatic measurement. Inductance, capacitance, resistance can be measured and displayed.
Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.


Technical parameters

 
Working condition -15ºC~40ºC RH<80%
Anti-interference principle Frequency conversion
Power supply AC 220V, 50/60Hz Generator can be used.
High voltage output AC 0.5KV~10KV (12kV optional) Every 0.1kV
Accuracy 2%
Max. current     200mA
Capacity 2000VA
Self-excitation power AC 0V~50V/15A 45HZ/55HZ  47.5HZ/52.5HZ
55HZ/65HZ  57.5HZ/62.5HZ
Automatic dual frequency
Resolution tgδ: 0.001% Cx: 0.001pF
Accuracy tgδ: ±(reading*1.0%+0.040%)
C x: ±(reading*1.0%+1.00PF)
Measurement range tgδ Without limit
C x 15pF < Cx < 300nF
10KV Cx < 60 nF
 5KV Cx < 150 nF
 1KV Cx < 300 nF
CVT test Cx < 300 nF
LCR measurement range L>20H(2kV) R>10KΩ(2kV)
LCR measurement accuracy 0.1% Angle resolution 0.01
CVT ratio range 10~10000
CVT ratio accuracy 0.1%
CVT ratio resolution 0.01
Dimension Main unit: 470(L)×370(W)×380(H)
Accessory box: 430(L)×350(W)×130(H)
Memory capacity 200 groups, USB flash disk storage is supported.
Weight Main unit: 22.75Kg
Accessory box: 5.25Kg

Accessories

1.Carrying case         1PCS
2.HV test lead 8m       1PCS
3.LV test lead 8m        1PCS
4.Power cord 1.8m       1PCS
5.CVT Connecting lead 5m   1PCS
6.Ground lead 2m       1PCS
7.Print paper          1PCS
8.10A fuse           1 Rolls
9.User's Guide        1PCS
10.Factory Test report   1PCS

Optional accessories

Oil Test Cell           1PCS     
Heating Controller      1PCS


Company Profile:

HV Hipot Electric Co., Ltd is a professional manufacturer specialized in electrical safety testing equipment, especially high voltage testing equipment.

We had researched and produced and sell test equipment for over ten years,our products have been sold well nationwide and worldwide.

Our test equipment can test for various kinds of electrical products, such as GIS Systems,Transformers,Generators,Circuit Breakers, Relays,Surge Arresters, Insulators, Cables, Casings and CT/ PTs, etc.

GD6800 HV HIPOT Capacitance and Transformer Tan Delta Tester
GD6800 HV HIPOT Capacitance and Transformer Tan Delta Tester
GD6800 HV HIPOT Capacitance and Transformer Tan Delta Tester


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier