GD6800 HV HIPOT Capacitance and Transformer Tan Delta Tester
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | yes |
| Display: | Digital |
Diamond Member Since 2011
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Year of Establishment
2006-11-08
Number of Employees
68
Find Similar Products
Basic Info.
- Model NO.
- GD6800
- Usage
- Electric Component Tester
- Type
- Capacitance Measuring Tester
- Environment
- Room Temperature
- Warranty
- With Warranty
- Power Source
- AC 85V-265V
- Weight
- 〉10Kg
- Installation
- Direct Connected
- Customized
- Customized
- Anti-interference principle
- Frequency conversion method
- Working condition
- -15degree~40degree, RH<80%
- Power supply
- AC 220V, Generator can be used.
- High voltage output
- 0.5KV~10KV, Every 0.1kV
- Self-excitation power
- AC 0V~50V/15A
- Dimension
- 445*345*380mm
- Product name
- Capacitance and Dissipation Factor Tester Tan Delt
- Transport Package
- Wooden Box
- Specification
- ISO9001
- Trademark
- HV Hipot
- Origin
- China
- Production Capacity
- 9000 Sets/Year
Product Description
GD6800 Transformer CVT Capacitance and Dissipation Factor Tester
High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.
Features
Touch LCD screen display.
Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
The instrument data can be exported through U disk.
Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
LCR automatic measurement. Inductance, capacitance, resistance can be measured and displayed.
Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Technical parameters
Accessories
1.Carrying case 1PCS
2.HV test lead 8m 1PCS
3.LV test lead 8m 1PCS
4.Power cord 1.8m 1PCS
5.CVT Connecting lead 5m 1PCS
6.Ground lead 2m 1PCS
7.Print paper 1PCS
8.10A fuse 1 Rolls
9.User's Guide 1PCS
10.Factory Test report 1PCS
Optional accessories
Oil Test Cell 1PCS
Heating Controller 1PCS
Company Profile:
HV Hipot Electric Co., Ltd is a professional manufacturer specialized in electrical safety testing equipment, especially high voltage testing equipment.
We had researched and produced and sell test equipment for over ten years,our products have been sold well nationwide and worldwide.
Our test equipment can test for various kinds of electrical products, such as GIS Systems,Transformers,Generators,Circuit Breakers, Relays,Surge Arresters, Insulators, Cables, Casings and CT/ PTs, etc.


Product Description
GD6800 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.
Features
Touch LCD screen display.
Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
The instrument data can be exported through U disk.
Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
LCR automatic measurement. Inductance, capacitance, resistance can be measured and displayed.
Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Technical parameters
| Working condition | -15ºC~40ºC | RH<80% | |||
| Anti-interference principle | Frequency conversion | ||||
| Power supply | AC 220V, 50/60Hz | Generator can be used. | |||
| High voltage output | AC 0.5KV~10KV (12kV optional) | Every 0.1kV | |||
| Accuracy | 2% | ||||
| Max. current | 200mA | ||||
| Capacity | 2000VA | ||||
| Self-excitation power | AC 0V~50V/15A | 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic dual frequency |
|||
| Resolution | tgδ: 0.001% | Cx: 0.001pF | |||
| Accuracy | tgδ: ±(reading*1.0%+0.040%) | ||||
| C x: ±(reading*1.0%+1.00PF) | |||||
| Measurement range | tgδ | Without limit | |||
| C x | 15pF < Cx < 300nF | ||||
| 10KV | Cx < 60 nF | ||||
| 5KV | Cx < 150 nF | ||||
| 1KV | Cx < 300 nF | ||||
| CVT test | Cx < 300 nF | ||||
| LCR measurement range | L>20H(2kV) | R>10KΩ(2kV) | |||
| LCR measurement accuracy | 0.1% | Angle resolution | 0.01 | ||
| CVT ratio range | 10~10000 | ||||
| CVT ratio accuracy | 0.1% | ||||
| CVT ratio resolution | 0.01 | ||||
| Dimension | Main unit: 470(L)×370(W)×380(H) | ||||
| Accessory box: 430(L)×350(W)×130(H) | |||||
| Memory capacity | 200 groups, USB flash disk storage is supported. | ||||
| Weight | Main unit: 22.75Kg | ||||
| Accessory box: 5.25Kg | |||||
Accessories
1.Carrying case 1PCS
2.HV test lead 8m 1PCS
3.LV test lead 8m 1PCS
4.Power cord 1.8m 1PCS
5.CVT Connecting lead 5m 1PCS
6.Ground lead 2m 1PCS
7.Print paper 1PCS
8.10A fuse 1 Rolls
9.User's Guide 1PCS
10.Factory Test report 1PCS
Optional accessories
Oil Test Cell 1PCS
Heating Controller 1PCS
Company Profile:
HV Hipot Electric Co., Ltd is a professional manufacturer specialized in electrical safety testing equipment, especially high voltage testing equipment.
We had researched and produced and sell test equipment for over ten years,our products have been sold well nationwide and worldwide.
Our test equipment can test for various kinds of electrical products, such as GIS Systems,Transformers,Generators,Circuit Breakers, Relays,Surge Arresters, Insulators, Cables, Casings and CT/ PTs, etc.


Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Transformer Tester
- Capacitance & Tan Delta Tester
- GD6800 HV HIPOT Capacitance and Transformer Tan Delta Tester
Related Categories
Hot Searches
More