• Impulse Voltage Generator Lightning Impulse Test for Transformer, Switchgear, Circuit Breaker

Impulse Voltage Generator Lightning Impulse Test for Transformer, Switchgear, Circuit Breaker

After-sales Service: Onsite commissioning
Warranty: ONE Year
Impulse Test: Impulse Voltage Test
Impulse voltage grade: 300kV
Impulse capacitance: 0.666µF
Transport Package: Wooden Case
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDCY-300/30
Specification
SGS, ISO
Trademark
HVHIPOT
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
500PCS/Year

Product Description

General Information

This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers (capacity below 5000kVA), CT/PT at 35kV or below.


Specification
 
Nominal voltage ±300kV
Rated energy 30kJ(5kJ/stage)
Impulse capacitance 0.666µF
Number of Stage 3
Charging voltage per stage ±100kV
Rated level capacitance 2µF (each impulse capacitor 2µF at 100kV, total 3pcs)
Output voltage waveform (Load capacitance is 300-3000pF) T1= 1.2µs±30%, T2=50µs±20%, peak voltage error≤3% standard lightning impulse voltage full wave.
Impulse voltage waveform parameters and error are accorded with national requirements of GB311.1 and GB16927.1 standard and IEC standard.
Output Voltage Efficiency Standard lightning wave ≥90% when load capacitance is below 1000pF, standard lightning wave ≥85% when load capacitance is below 2000pF
Locking range level voltage is within the range of 20%-100% of rated voltage, positive and negative locking range no less than 25%
Out-of-control rate of synchronous discharge <5%
Min. output voltage  ≥±10% of rated voltage
Instability of charging voltage <±1.0%
Continuous time Above 2/3 of rated voltage, continuous working when charge anddischarge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.

Impulse Voltage Generator Lightning Impulse Test for Transformer, Switchgear, Circuit Breaker
Impulse Voltage Generator Lightning Impulse Test for Transformer, Switchgear, Circuit Breaker
Impulse Voltage Generator Lightning Impulse Test for Transformer, Switchgear, Circuit Breaker



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now