2.2. Transient capture function
Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctuations, voltage current surge, sag and short supply interruption, temporary overvoltage, impact current and Current voltage instantaneous distortion. Instruments can store 150 sets of transient waveform at the same time.
2.3. Starting current monitoring
Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity. Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4 channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and waveform curve of each cycle in 100s.
2.4. Trend chart recording and storing function
Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).
2.5. Alarm function
Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as: voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distortion. You can configure 40 different alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.
2.6. Snapshot function
Any screen can be saved(screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.
2.7. Communication function
Communicate with computer via USB, Monitoring software can display waveform of power quality analysis, read of the transient waveform, trend chart recording, alarm log, screenshots, and display on the computer.
2.8. Setting function
The user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase curve colours.
Choice of type of connection to the network.
Configuration of the type of the current sensors and voltage ratios.
2.9. Help menu
Every stage of operation can press the "help" key to obtain relevant information.
Specifications
Influence factor | Test item | Base condition | Working condition |
Environment temperature | All parameters | (23±2)°C | -10°C~ 40°C |
Relative humidity | All parameters | 40%~ 60% | <80% |
Phase-to-neutral voltage | All parameters | (100±1%)V | 1.0V~ 1000V |
Phase-to-phase voltage | True RMS phase-to-phase voltage | (200±1%)V | 1.0V~ 2000V |
Current | True RMS current | (5±1%)A | 10mA~ 10A |
Network frequency | All parameters | 50Hz±0.1Hz | 40Hz~ 70Hz |
Phase shift | Active power and active energy | Cosφ=1 | Cosφ: 0.2~ 1.0 |
Reactive power and reactive energy | Sinφ=1 | Sinφ: 0.2~ 1.0 | |
Harmonic | All parameters | <0.1% | 0.0%~ 100% |
Voltage unbalance | All parameters | <10% | 0.0%~ 100% |
Working voltage of device | All parameters | DC9.8V±0.1V | DC9.5V~ 10.5V |
External electric field, magnetic field |
All parameters | Should be avoided | |
Test position | Measured related parameters of current | Tested wire at the center of clamp. |