HVHIPOT Impulse Voltage/Current Test System (GDCL-V)

Product Details
Customization: Available
After-sales Service: YES
Warranty: 1
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
  • HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
  • HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
  • HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
  • HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
  • HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
Find Similar Products

Basic Info.

Model NO.
GDCL-V
Transport Package
Wooden Case
Specification
SGS, ISO
Trademark
HVHIPOT
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
500PCS/Year

Product Description

HVHIPOT Impulse Voltage/Current Test System (GDCL-V)

General Information

It is mainly used for composite wave testing of level III SPD,to generate bigger lightning impulse and current.This model 20kV/10kA is designed according to IEC61000-4-5 and GB/T17626.5-1999, the stipulation of Voltage wave&combination waveform, and signal generator features and performance, coupling and decoupling network.Also it is designed accorded with IEC61643-11 and GB/T18802.1-2002, the stipulation of Level I and II SPD impulse voltage testing, and level III SPD composite wave testing.


Main Features and Specifications

1. Waveform requirement and output range

  • Short-circuit current Isc: wave-front time 8μS±10%, half peak time 20μS±10%, peak value ±10%
  • At wave crest, ≥5% peak value of Current overshoot or vibration is not permitted.If current wave has reversed polarity vibration, then ≤20% peak value. Short-circuit current peak value 1kA-10kA.
  • Virtual impedance: 2Ω

2. Pointer voltmeter and digital voltmeter display for charging voltage. Positive shock and negative shock can be realized.

3. With impulse current display, accuracy ±1%

4. Output voltage measurement

  • With impulse voltage divider(voltage ratio accuracy ±1%), output to BNC socket of panel, for oscillograph connection.

5. Protection device

  • The instrument has enough safety device, ensure safe operation.

6. Rated parameters

  • Power input: 220V, AC, 5kVA
  • Rated charging voltage: 20kV
  • Total capacitance: 9μF×1
  • Rated capacity: 18kJ.

HVHIPOT Impulse Voltage/Current Test System (GDCL-V)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier